| Section 1. Identification | |||
|---|---|---|---|
| Chemical Name | vinyl butyrate | CAS No. | 123-20-6 |
| Synonyms | butyricacid,vinyl ester | Chinese Name | 正丁酸乙烯酯 |
| Molecular Formula | (C_6H_10()_2) | Molecular Weight | 114.1424 |
| UN No. | 2838 | Data Source | PubChem (NIH/NLM) |
| GHS Hazard Classification | |
|---|---|
| Signal Word | DANGER |
| Pictograms | GHS02 · Flammable GHS07 · Irritant |
| Hazard Statements | H225H332 |
| Precautionary Statements | P210P233P240P241P242P243P261P271P280P303+P361+P353P304+P340P317P370+P378P403+P235P501 |
| Contents | |||
|---|---|---|---|
| Section 2 | Hazards Identification | Section 4 | First-Aid Measures |
| Section 5 | Fire-Fighting Measures | Section 6 | Accidental Release Measures |
| Section 7 | Handling and Storage | Section 8 | Exposure Controls / Personal Protection |
| Section 9 | Physical and Chemical Properties | Section 10 | Stability and Reactivity |
| Section 11 | Toxicological Information | Section 14 | Transport Information |
H225 (100%): Highly Flammable liquid and vapor [Danger Flammable liquids]
H332 (95.1%): Harmful if inhaled [Warning Acute toxicity, inhalation]
P210, P233, P240, P241, P242, P243, P261, P271, P280, P303+P361+P353, P304+P340, P317, P370+P378, P403+P235, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 41 reports by companies from 2 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious); polymerization hazard]:
Refer to the "General First Aid" section. Specific First Aid: Wash skin with soap and water. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)
General First Aid:
· Call 911 or emergency medical service.
· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.
· Move victim to fresh air if it can be done safely.
· Administer oxygen if breathing is difficult.
· If victim is not breathing:
-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.
-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).
-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.
· Remove and isolate contaminated clothing and shoes.
· For minor skin contact, avoid spreading material on unaffected skin.
· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.
· For severe burns, immediate medical attention is required.
· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.
· Keep victim calm and warm.
· Keep victim under observation.
· For further assistance, contact your local Poison Control Center.
· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.
Specific First Aid:
· Wash skin with soap and water.
· In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin.
In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious); polymerization hazard]:
CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient.
SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. Do not use dry chemical extinguishers to control fires involving nitromethane (UN1261) or nitroethane (UN2842).
LARGE FIRE: Water spray, fog or alcohol-resistant foam. Avoid aiming straight or solid streams directly onto the product. If it can be done safely, move undamaged containers away from the area around the fire.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· Keep unauthorized personnel away.
· Stay upwind, uphill and/or upstream.
· Ventilate closed spaces before entering, but only if properly trained and equipped.
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.
· All equipment used when handling the product must be grounded.
· Do not touch or walk through spilled material.
· Stop leak if you can do it without risk.
· Prevent entry into waterways, sewers, basements or confined areas.
· A vapor-suppressing foam may be used to reduce vapors.
· Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers.
· Use clean, non-sparking tools to collect absorbed material.
Large Spill
· Dike far ahead of liquid spill for later disposal.
· Water spray may reduce vapor, but may not prevent ignition in closed spaces.
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious); polymerization hazard]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Immediate precautionary measure
· Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
· Consider initial downwind evacuation for at least 300 meters (1000 feet).
· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious); polymerization hazard]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.
LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
· Wear positive pressure self-contained breathing apparatus (SCBA).
· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.
CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient.
Small Fire
· Dry chemical, CO2, water spray or alcohol-resistant foam.
· Do not use dry chemical extinguishers to control fires involving nitromethane (UN1261) or nitroethane (UN2842).
Large Fire
· Water spray, fog or alcohol-resistant foam.
· Avoid aiming straight or solid streams directly onto the product.
· If it can be done safely, move undamaged containers away from the area around the fire.
Fire Involving Tanks, Rail Tank Cars or Highway Tanks
· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.
· Cool containers with flooding quantities of water until well after fire is out.
· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.
· ALWAYS stay away from tanks in direct contact with flames.
· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious); polymerization hazard]:
Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
Vinyl butyrate, stabilized appears as a colorless liquid. Less dense than water. Vapors heavier than air. Used to make plastics and paints.
Colorless liquid; [CAMEO]
68 °F (NFPA, 2010)
Boiling point
Heat of sublimation
Vapor pressure
Flammable agents - 3rd degree
Reactive agents - 2nd degree
FCS -> FDA Inventory of Food Contact Substances Listed in 21 CFR
Solvents -> Esters (<C12)
Highly flammable. Slightly soluble in water.
Esters, Sulfate Esters, Phosphate Esters, Thiophosphate Esters, and Borate Esters
Hydrocarbons, Aliphatic Unsaturated
Polymerizable Compounds
Highly Flammable
Polymerizable
Strong Reducing Agent
Peroxidizable Compound
VINYL BUTYRATE is an ester. Esters react with acids to liberate heat along with alcohols and acids. Strong oxidizing acids may cause a vigorous reaction that is sufficiently exothermic to ignite the reaction products. Heat is also generated by the interaction of esters with caustic solutions. Flammable hydrogen is generated by mixing esters with alkali metals and hydrides.
Neurotoxin - Acute solvent syndrome
Dermatotoxin - Skin burns.
2838 129P
Flammable Liquid