English Safety Data Sheet Database 中文版 MSDS

Rubidium hydroxide

CAS No. 1310-82-3 | PubChem CID 62393
Section 1. Identification
Chemical NameRubidium hydroxide CAS No.1310-82-3
Synonymsrubidiumhydroxide Chinese Name氢氧化铷
Molecular FormulaRbOH Molecular Weight102.4751
UN No.2678 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS05 · Corrosive GHS07 · Irritant
Hazard Statements H302H312H314H332
Precautionary Statements P260P261P264P270P271P280P301+P317P301+P330+P331P302+P352P302+P361+P354P304+P340P305+P354+P338P316P317P321P330P362+P364P363P405P501

Section 2. Hazards Identification

H302 (98.6%): Harmful if swallowed [Warning Acute toxicity, oral]

H312 (55.4%): Harmful in contact with skin [Warning Acute toxicity, dermal]

H314 (95.9%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]

H332 (55.4%): Harmful if inhaled [Warning Acute toxicity, inhalation]

P260, P261, P264, P270, P271, P280, P301+P317, P301+P330+P331, P302+P352, P302+P361+P354, P304+P340, P305+P354+P338, P316, P317, P321, P330, P362+P364, P363, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 74 reports by companies from 6 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

Refer to the "General First Aid" section. Specific First Aid: For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

SMALL FIRE: Dry chemical, CO2 or water spray.

LARGE FIRE: Dry chemical, CO2, alcohol-resistant foam or water spray. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· Do not touch damaged containers or spilled material unless wearing appropriate protective clothing.

· Stop leak if you can do it without risk.

· Prevent entry into waterways, sewers, basements or confined areas.

· Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers.

· DO NOT GET WATER INSIDE CONTAINERS.

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

· For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.

· For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind direction, as necessary.

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

Section 7. Handling and Storage

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

1.8 [mg/m3]

19 [mg/m3]

120 [mg/m3]

Small Fire

· Dry chemical, CO2 or water spray.

Large Fire

· Dry chemical, CO2, alcohol-resistant foam or water spray.

· If it can be done safely, move undamaged containers away from the area around the fire.

· Dike runoff from fire control for later disposal.

Fire Involving Tanks, Rail Tank Cars or Highway Tanks

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Do not get water inside containers.

· Cool containers with flooding quantities of water until well after fire is out.

· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.

· ALWAYS stay away from tanks in direct contact with flames.

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

Rubidium hydroxide appears as a grayish-white solid. It is very irritating to skin and eyes. Denser than water. It is used in electric storage batteries.

Rubidium hydroxide, solution appears as a clear aqueous solution. Very caustic. Very irritating to skin and eyes. Used in electric storage batteries.

Greyish-white deliquescent solid; [Merck Index] 50% aqueous solution: Clear colorless liquid; [Acros Organics MSDS]

V (@25 °C)

3 .203 @ 11°C

Metals -> Metals, Inorganic Compounds

Corrosives

Section 10. Stability and Reactivity

Extremely hygroscopic. Absorbs carbon dioxide from the air. May generate sufficient heat when dissolved in water to cause the solution to boil.

Absorbs carbon dioxide from the air. May generate large amounts of heat when diluted with water.

Bases, Strong

Water and Aqueous Solutions

Water-Reactive

A strong base. Forms caustic solution in water with heat generation [Merck 11th ed. 1989]. May generate sufficient heat when dissolved in water to cause the solution to boil.

A strong base. Forms caustic solution in water [Merck 11th ed. 1989].

Section 11. Toxicological Information

Occupational hepatotoxin - Secondary hepatotoxins: the potential for toxic effect in the occupational setting is based on cases of poisoning by human ingestion or animal experimentation.

Dermatotoxin - Skin burns.

Toxic Pneumonitis - Inflammation of the lungs induced by inhalation of metal fumes or toxic gases and vapors.

Rubidium Hydroxide

PDF Document

Inadequate information to assess carcinogenic potential

PPRTV Current

Section 14. Transport Information

Corrosive

Source: PubChem CID 62393 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:53:25.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.