| Section 1. Identification | |||
|---|---|---|---|
| Chemical Name | Dibasic lead phosphite | CAS No. | 1344-40-7 |
| Synonyms | dibasic leadphosphite; lead phosphite,dibasic | Chinese Name | 亚磷酸二氢铅 |
| Molecular Formula | 2PbO | Molecular Weight | 742.6 |
| UN No. | 1325 | Data Source | PubChem (NIH/NLM) |
| GHS Hazard Classification | |
|---|---|
| Signal Word | DANGER |
| Pictograms | GHS02 · Flammable GHS08 · Health Hazard |
| Hazard Statements | H228H350H360H370H372 |
| Precautionary Statements | P203P210P240P241P260P264P270P280P308+P316P318P319P321P370+P378P405P501 |
| Contents | |||
|---|---|---|---|
| Section 2 | Hazards Identification | Section 4 | First-Aid Measures |
| Section 5 | Fire-Fighting Measures | Section 6 | Accidental Release Measures |
| Section 7 | Handling and Storage | Section 8 | Exposure Controls / Personal Protection |
| Section 9 | Physical and Chemical Properties | Section 10 | Stability and Reactivity |
| Section 11 | Toxicological Information | Section 14 | Transport Information |
H228: Flammable solid [Danger Flammable solids]
H350: May cause cancer [Danger Carcinogenicity]
H360: May damage fertility or the unborn child [Danger Reproductive toxicity]
H370: Causes damage to organs [Danger Specific target organ toxicity, single exposure]
H372: Causes damage to organs through prolonged or repeated exposure [Danger Specific target organ toxicity, repeated exposure]
P203, P210, P240, P241, P260, P264, P270, P280, P308+P316, P318, P319, P321, P370+P378, P405, and P501 (click each P-code to see the statement)
Excerpt from ERG Guide 133 [Flammable Solids]:
Refer to the "General First Aid" section. Specific First Aid: Removal of solidified molten material from skin requires medical assistance. (ERG, 2024)
General First Aid:
· Call 911 or emergency medical service.
· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.
· Move victim to fresh air if it can be done safely.
· Administer oxygen if breathing is difficult.
· If victim is not breathing:
-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.
-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).
-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.
· Remove and isolate contaminated clothing and shoes.
· For minor skin contact, avoid spreading material on unaffected skin.
· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.
· For severe burns, immediate medical attention is required.
· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.
· Keep victim calm and warm.
· Keep victim under observation.
· For further assistance, contact your local Poison Control Center.
· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.
Specific First Aid:
· Removal of solidified molten material from skin requires medical assistance.
In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.
Excerpt from ERG Guide 133 [Flammable Solids]:
SMALL FIRE: Dry chemical, CO2, sand, earth, water spray or regular foam.
LARGE FIRE: Water spray, fog or regular foam. If it can be done safely, move undamaged containers away from the area around the fire.
FIRE INVOLVING METAL PIGMENTS OR PASTES (E.G. "ALUMINUM PASTE"): Aluminum Paste fires should be treated as a combustible metal fire. Use DRY sand, graphite powder, dry sodium chloride-based extinguishers or class D extinguishers. Also, see ERG Guide 170.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Cool containers with flooding quantities of water until well after fire is out. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· Keep unauthorized personnel away.
· Stay upwind, uphill and/or upstream.
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.
· Do not touch or walk through spilled material.
Small Dry Spill
· With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.
Large Spill
· Wet down with water and dike for later disposal.
· Prevent entry into waterways, sewers, basements or confined areas.
Excerpt from ERG Guide 133 [Flammable Solids]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 25 meters (75 feet) in all directions.
LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Immediate precautionary measure
· Isolate spill or leak area for at least 25 meters (75 feet) in all directions.
· Consider initial downwind evacuation for at least 100 meters (330 feet).
· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.
Excerpt from ERG Guide 133 [Flammable Solids]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Do not touch or walk through spilled material.
SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.
LARGE SPILL: Wet down with water and dike for later disposal. Prevent entry into waterways, sewers, basements or confined areas. (ERG, 2024)
· Wear positive pressure self-contained breathing apparatus (SCBA).
· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.
Biological Exposure Indices (BEI) [ACGIH] - Lead in blood = 200 ug/L (20 ug/100 ml); sampling time not critical; [ACGIH]
0.05 [mg/m3], as Pb
Small Fire
· Dry chemical, CO2, sand, earth, water spray or regular foam.
Large Fire
· Water spray, fog or regular foam.
· If it can be done safely, move undamaged containers away from the area around the fire.
Fire Involving Metal Pigments or Pastes (e.g. "Aluminum Paste")
· Aluminum Paste fires should be treated as a combustible metal fire. Use DRY sand, graphite powder, dry sodium chloride-based extinguishers or class D extinguishers. Also, see GUIDE 170.
Fire Involving Tanks, Rail Tank Cars or Highway Tanks
· Cool containers with flooding quantities of water until well after fire is out.
· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.
· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.
· ALWAYS stay away from tanks in direct contact with flames.
Excerpt from ERG Guide 133 [Flammable Solids]:
Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
1.48e+03
Lead phosphite, dibasic is a finely ground white crystalline solid. It is not soluble in water. It may be toxic by ingestion or skin absorption. The material can be readily ignited from exposure to heat or external sparks. When so ignited it burns vigorously and persistently.
White solid; Insoluble in water; [CAMEO] Pale yellow solid; [IARC] White crystalline solid; Odorless; [Chem Service MSDS]
Metals -> Lead Compounds, Inorganic
Insoluble in water.
Salts, Basic
Highly Flammable
LEAD PHOSPHITE, DIBASIC is self-reactive. A fiber drum of lead diphosphite caught fire apparently without any external cause. A gradual decomposition appears to have taken place, yielding lead phosphate, water, and phosphine. Phosphine, in turn, is spontaneously flammable in air and was probably the ignition source for the resulting fire [Kirk and Othmer 10:489. 1947]. Reacts violently with hydrogen sulfide [Bretherick 1979. p. 977-978].
Neurotoxin - Predominantly motor
Occupational hepatotoxin - Secondary hepatotoxins: the potential for toxic effect in the occupational setting is based on cases of poisoning by human ingestion or animal experimentation.
Nephrotoxin - The chemical is potentially toxic to the kidneys in the occupational setting.
Hemolytic anemia - Decreased hemoglobin or number of red blood cells.
Reproductive Toxin - A chemical that is toxic to the reproductive system, including defects in the progeny and injury to male or female reproductive function. Reproductive toxicity includes developmental effects. See Guidelines for Reproductive Toxicity Risk Assessment.
IARC Carcinogen - Class 2: International Agency for Research on Cancer classifies chemicals as probable (2a), or possible (2b) human carcinogens.
NTP Carcinogen - Reasonably anticipated to be a human carcinogen.
ACGIH Carcinogen - Confirmed Animal.
Flammable Solid