English Safety Data Sheet Database 中文版 MSDS

Calcium perchlorate

CAS No. 13477-36-6 | PubChem CID 61629
Section 1. Identification
Chemical NameCalcium perchlorate CAS No.13477-36-6
Synonymscalciumperchlorate Chinese Name高氯酸钙
Molecular FormulaCa(ClO4)2 Molecular Weight238.98
UN No.1455 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS03 · Oxidizer
Hazard Statements H271
Precautionary Statements P210P220P280P283P306+P360P370+P378P371+P380+P375P420P501

Section 2. Hazards Identification

H271 (97.4%): May cause fire or explosion; strong Oxidizer [Danger Oxidizing liquids; Oxidizing solids]

P210, P220, P280, P283, P306+P360, P370+P378, P371+P380+P375, P420, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 39 reports by companies from 2 notifications to the ECHA C&L Inventory.

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

Excerpt from ERG Guide 140 [Oxidizers]:

Refer to the "General First Aid" section. Specific First Aid: Contaminated clothing may be a fire risk when dry. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· Contaminated clothing may be a fire risk when dry.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 140 [Oxidizers]:

SMALL FIRE: Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.

LARGE FIRE: Flood fire area with water from a distance. Do not move cargo or vehicle if cargo has been exposed to heat. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: For ammonium nitrate products: Do not fight cargo fire. Withdraw, evacuate and isolate area for at least 1600 meters (1 mile). Treat as an explosive (ERG Guide 112). Do not enter area for 24 hours or until expert advice has been provided. Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· Keep combustibles (wood, paper, oil, etc.) away from spilled material.

· Do not touch damaged containers or spilled material unless wearing appropriate protective clothing.

· Stop leak if you can do it without risk.

· Do not get water inside containers.

Small Dry Spill

· With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.

Small Liquid Spill

· Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal.

Large Spill

· Dike far ahead of liquid spill for later disposal.

Excerpt from ERG Guide 140 [Oxidizers]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. If ammonium nitrate products are in a tank, rail car or truck and involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, initiate evacuation including emergency responders for 1600 meters (1 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

· Consider initial downwind evacuation for at least 100 meters (330 feet).

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

· If ammonium nitrate products are in a tank, rail car or truck and involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, initiate evacuation including emergency responders for 1600 meters (1 mile) in all directions.

Section 7. Handling and Storage

Excerpt from ERG Guide 140 [Oxidizers]:

Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Do not get water inside containers.

SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.

SMALL LIQUID SPILL: Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

Small Fire

· Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.

Large Fire

· Flood fire area with water from a distance.

· Do not move cargo or vehicle if cargo has been exposed to heat.

· If it can be done safely, move undamaged containers away from the area around the fire.

Fire Involving Tanks, Rail Tank Cars or Highway Tanks

· For ammonium nitrate products: Do not fight cargo fire. Withdraw, evacuate and isolate area for at least 1600 meters (1 mile). Treat as an explosive (GUIDE 112). Do not enter area for 24 hours or until expert advice has been provided.

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Cool containers with flooding quantities of water until well after fire is out.

· ALWAYS stay away from tanks in direct contact with flames.

· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.

Excerpt from ERG Guide 140 [Oxidizers]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

Calcium perchlorate is a white to yellow crystalline solid. Density 2.651 g / cm3. Contact may irritate skin, eyes, and mucous membranes. May be toxic by ingestion.

White solid; [Hawley] White to yellow solid; [CAMEO] Powder; [MSDSonline]

Other Classes -> Perchlorates

Section 10. Stability and Reactivity

Water soluble.

Oxidizing Agents, Strong

Explosive

Strong Oxidizing Agent

A strong oxidizing agent. Can react with reducing agents to generate heat and products that may be gaseous (causing pressurization in closed containers). The products may themselves be capable of further reactions (such as combustion in the air). Redox reactions can be rapid or even explosive, but often requires initiation (heat, spark, catalyst, addition of a solvent). Consequently explosive mixtures with reducing agents often persist unchanged for long periods. Such systems are typically mixtures of solids, but may involve any combination of physical states. Can react violently with active metals, cyanides, esters, and thiocyanates. May cause the acceleration of the burning of combustible materials. Prolonged exposure to heat of flames may result in an explosion.

Section 11. Toxicological Information

Methemoglobinemia - The presence of increased methemoglobin in the blood; the compound is classified as secondary toxic effect

Section 14. Transport Information

Oxidizer

Source: PubChem CID 61629 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:05:56.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.