| Section 1. Identification | |||
|---|---|---|---|
| Chemical Name | chlorine pentafluoride | CAS No. | 13637-63-3 |
| Synonyms | — | Chinese Name | 五氟化氯 |
| Molecular Formula | CIF5 | Molecular Weight | 130.445 |
| UN No. | 2548 | Data Source | PubChem (NIH/NLM) |
| GHS Hazard Classification | |
|---|---|
| Signal Word | DANGER |
| Pictograms | GHS03 · Oxidizer GHS04 · Compressed Gas GHS05 · Corrosive GHS06 · Acute Toxic |
| Hazard Statements | H270H280H314H330 |
| Precautionary Statements | P220P244P260P264P271P280P284P301+P330+P331P302+P361+P354P304+P340P305+P354+P338P316P320P321P363P370+P376P403P403+P233P405P410+P403P501 |
| Contents | |||
|---|---|---|---|
| Section 2 | Hazards Identification | Section 4 | First-Aid Measures |
| Section 5 | Fire-Fighting Measures | Section 6 | Accidental Release Measures |
| Section 7 | Handling and Storage | Section 8 | Exposure Controls / Personal Protection |
| Section 9 | Physical and Chemical Properties | Section 10 | Stability and Reactivity |
| Section 11 | Toxicological Information | Section 14 | Transport Information |
H270 (100%): May cause or intensify fire; oxidizer [Danger Oxidizing gases]
H280 (100%): Contains gas under pressure; may explode if heated [Warning Gases under pressure]
H314 (100%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]
H330 (100%): Fatal if inhaled [Danger Acute toxicity, inhalation]
P220, P244, P260, P264, P271, P280, P284, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P316, P320, P321, P363, P370+P376, P403, P403+P233, P405, P410+P403, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 111 reports by companies from 1 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:
Refer to the "General First Aid" section. Specific First Aid: Clothing frozen to the skin should be thawed before being removed. (ERG, 2024)
General First Aid:
· Call 911 or emergency medical service.
· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.
· Move victim to fresh air if it can be done safely.
· Administer oxygen if breathing is difficult.
· If victim is not breathing:
-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.
-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).
-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.
· Remove and isolate contaminated clothing and shoes.
· For minor skin contact, avoid spreading material on unaffected skin.
· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.
· For severe burns, immediate medical attention is required.
· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.
· Keep victim calm and warm.
· Keep victim under observation.
· For further assistance, contact your local Poison Control Center.
· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.
Specific First Aid:
· Clothing frozen to the skin should be thawed before being removed.
In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:
CAUTION: These materials do not burn but will support combustion. Some will react violently with water.
SMALL FIRE: Contain fire and let burn. If fire must be fought, water spray or fog is recommended. Water only; no dry chemical, CO2 or Halon®. Do not get water inside containers. If it can be done safely, move undamaged containers away from the area around the fire. Damaged cylinders should be handled only by specialists.
FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· Keep unauthorized personnel away.
· Stay upwind, uphill and/or upstream.
· Many gases are heavier than air and will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).
· Ventilate closed spaces before entering, but only if properly trained and equipped.
· Do not touch or walk through spilled material.
· Keep combustibles (wood, paper, oil, etc.) away from spilled material.
· Stop leak if you can do it without risk.
· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.
· Do not direct water at spill or source of leak.
· If possible, turn leaking containers so that gas escapes rather than liquid.
· Prevent entry into waterways, sewers, basements or confined areas.
· Isolate area until gas has dispersed.
· Ventilate the area.
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.
SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 2548 datasheet.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Immediate precautionary measure
· Isolate spill or leak area for at least 100 meters (330 feet) in all directions.
· See Table 1 - Initial Isolation and Protective Action Distances.
· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.
Small spill:
- ISOLATE in all directions: 100 m (300 ft)
Large spill:
- ISOLATE in all directions: 800 m (2500 ft)
- PROTECT people from downwind during DAY time: 0.5 km (0.3 mi)
- PROTECT people from downwind during NIGHT time: 2.5 km (1.6 mi)
- PROTECT people from downwind during DAY time: 5.1 km (3.2 mi)
- PROTECT people from downwind during NIGHT time: 11.0+ km (7.0+ mi)
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:
Do not touch or walk through spilled material. Keep combustibles (wood, paper, oil, etc.) away from spilled material. Stop leak if you can do it without risk. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Do not direct water at spill or source of leak. If possible, turn leaking containers so that gas escapes rather than liquid. Prevent entry into waterways, sewers, basements or confined areas. Isolate area until gas has dispersed. Ventilate the area. (ERG, 2024)
· Wear positive pressure self-contained breathing apparatus (SCBA).
· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.
· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.
TIH (Toxic Inhalation Hazard) - Term used to describe gases and volatile liquids that are toxic when inhaled. Some are TIH materials themselves, e.g., chlorine, and some release TIH gases when spilled in water, e.g., chlorosilanes. [ERG 2016].
1.0 [mg/m3], as F, inhalable fraction[German Research Foundation (DFG)]
AEGL 1: Notable discomfort, irritation, or certain asymptomatic non-sensory effects. However, the effects are not disabling and are transient and reversible upon cessation of exposure (Unit: ppm)
AEGL 2: Irreversible or other serious, long-lasting adverse health effects or an impaired ability to escape (Unit: ppm)
AEGL 3: Life-threatening health effects or death (Unit: ppm)
NR= Not recommended due to inadequate data. Absence of an AEGL-1 value does not imply that exposures below the AEGL-2 value are without adverse effects.
AEGLs Status: Final
0.015 [ppm]
0.17 [ppm]
8.0 [ppm]
2.5 [mg/m3], as F
1.7 ppm [From IDLH Table: Chlorine Pentafluoride] (NIOSH, 2024)
9.05 [mg/m3]
CAUTION: These materials do not burn but will support combustion. Some will react violently with water.
Small Fire
· Contain fire and let burn. If fire must be fought, water spray or fog is recommended.
· Water only; no dry chemical, CO2 or Halon®.
· Do not get water inside containers.
· If it can be done safely, move undamaged containers away from the area around the fire.
· Damaged cylinders should be handled only by specialists.
Fire Involving Tanks
· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.
· Cool containers with flooding quantities of water until well after fire is out.
· Do not direct water at source of leak or safety devices; icing may occur.
· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.
· ALWAYS stay away from tanks in direct contact with flames.
· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:
Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
Chlorine pentafluoride appears as a colorless gas with a sweet odor. Toxic by inhalation and an irritant to skin, eyes and mucus membranes. Corrosive. Heavier than air. Under prolonged exposure to fire or intense heat the containers may violently rupture or rocket. Used as an oxidizer in propellants.
Colorless gas with a sweet odor; [CAMEO]
-13.1 °C @760 [mm Hg]
5.332 g/L
Toxic Gases & Vapors -> Oxidizers
Corrosives
Reactive agents - 3rd degree
Reacts with water or moisture in the air to produce corrosive hydrofluoric acid and toxic chlorine gas. Interaction with ice at -100 °C, or with water vapor above 0 °C is extremely vigorous (Christe, K.O. Inorg. Chem. 1972 11, 1220). Hydrochloric acid fumes might also be generated upon reaction with water.
Oxidizing Agents, Strong
Halogenating Agents
Strong Oxidizing Agent
Water-Reactive
Air-Reactive
CHLORINE PENTAFLUORIDE is a strong oxidizing agent. Nonflammable, but likely to react vigorously on contact with combustible materials. Reacts violently with lithium, calcium. Emits highly toxic fluoride and chloride fumes when heated to decomposition. Extremely vigorous reaction with water, steam, even ice [Pilipovich D. et al., Inorg. Chem., 1967, 6, p. 1918]. Very vigorous reaction with anhydrous nitric acid even at -100 °C [Christie, K. O., Inorg. Chem. 1992, 11, p. 1220].
Dermatotoxin - Skin burns.
Toxic Pneumonitis - Inflammation of the lungs induced by inhalation of metal fumes or toxic gases and vapors.
LC50 (rat) = 122 ppm/1H
Poison Gas Oxidizer Corrosive