English Safety Data Sheet Database 中文版 MSDS

Difluorophosphoric acid

CAS No. 13779-41-4 | PubChem CID 61681
Section 1. Identification
Chemical NameDifluorophosphoric acid CAS No.13779-41-4
Synonymsphos-phorodifluoridic acid; difluopophosphoric acidanhydrous Chinese Name二氟磷酸(无水)
Molecular FormulaF2HPO2 Molecular Weight101.97730
UN No.1768 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS05 · Corrosive
Hazard Statements H314
Precautionary Statements P260P264P280P301+P330+P331P302+P361+P354P304+P340P305+P354+P338P316P321P363P405P501

Section 2. Hazards Identification

H314 (100%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]

P260, P264, P280, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P316, P321, P363, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 42 reports by companies from 3 notifications to the ECHA C&L Inventory.

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

Get medical attention as soon as possible following exposures to this compound.

INHALATION: remove from exposure and support respiration.

EYES: wash with copious volumes of water for at least 15 min.

SKIN: wash with large amounts of water for 15 min.

INGESTION: if victim is conscious, have him drink large amounts of water followed by milk or milk of magnesia. (USCG, 1999)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

SMALL FIRE: Dry chemical, CO2 or water spray.

LARGE FIRE: Dry chemical, CO2, alcohol-resistant foam or water spray. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· Do not touch damaged containers or spilled material unless wearing appropriate protective clothing.

· Stop leak if you can do it without risk.

· Prevent entry into waterways, sewers, basements or confined areas.

· Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers.

· DO NOT GET WATER INSIDE CONTAINERS.

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

· For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.

· For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind direction, as necessary.

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

Section 7. Handling and Storage

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

Small Fire

· Dry chemical, CO2 or water spray.

Large Fire

· Dry chemical, CO2, alcohol-resistant foam or water spray.

· If it can be done safely, move undamaged containers away from the area around the fire.

· Dike runoff from fire control for later disposal.

Fire Involving Tanks, Rail Tank Cars or Highway Tanks

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Do not get water inside containers.

· Cool containers with flooding quantities of water until well after fire is out.

· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.

· ALWAYS stay away from tanks in direct contact with flames.

Air line mask or self-contained breathing apparatus; full protective clothing. (USCG, 1999)

Section 9. Physical and Chemical Properties

Difluorophosphoric acid, anhydrous appears as a mobile colorless strongly fuming liquid. Density 1.583 g / cm3. Corrosive to glass, fabric, metals and tissue.

241 °F at 760 mmHg (USCG, 1999)

-139 °F (USCG, 1999)

1.583 at 77 °F (USCG, 1999) - Denser than water; will sink

Boiling point

Chemical shift

Heat of sublimation

Lineshape

Spin-spin coupling constant

Vapor pressure

Corrosives

Section 10. Stability and Reactivity

Fumes in air. Reacts vigorously with water to form corrosive and toxic hydrofluoric acid and heat.

Acids, Strong Non-oxidizing

Acyl Halides, Sulfonyl Halides, and Chloroformates

Fluoride Salts, Soluble

Water-Reactive

DIFLUOROPHOSPHORIC ACID, ANHYDROUS reacts exothermically with chemical bases (examples: amines, amides, and inorganic hydroxides). These reactions can generate dangerously large amounts of heat in small spaces. Reacts vigorously with water to form corrosive and toxic hydrofluoric acid and heat. Reacts with active metals, including such structural metals as aluminum and iron, to release hydrogen, a flammable gas. Can initiate the polymerization of certain alkenes. Reacts with cyanide compounds to release gaseous hydrogen cyanide. Generates flammable and/or toxic gases in contact with dithiocarbamates, isocyanates, mercaptans, nitrides, nitriles, sulfides, and strong reducing agents. Additional gas-generating reactions occur with sulfites, nitrites, thiosulfates (to give H2S and SO3), dithionites (SO2), and carbonates. May catalyze (increase the rate of) chemical reactions.

Section 14. Transport Information

Corrosive

Source: PubChem CID 61681 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:36:25.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.