| Section 1. Identification | |||
|---|---|---|---|
| Chemical Name | Magnesium peroxide (Mg(O2)) | CAS No. | 14452-57-4 |
| Synonyms | magnesium dioxide; magnesium peroxide | Chinese Name | 过氧化镁 |
| Molecular Formula | MgO2 | Molecular Weight | 56.3038 |
| UN No. | 1476 | Data Source | PubChem (NIH/NLM) |
| GHS Hazard Classification | |
|---|---|
| Signal Word | DANGER |
| Pictograms | GHS03 · Oxidizer GHS05 · Corrosive GHS07 · Irritant |
| Hazard Statements | H271H272H314H302H335 |
| Precautionary Statements | P210P220P260P264P280P283P301+P330+P331P302+P361+P354P304+P340P305+P354+P338P306+P360P316P321P363P370+P378P371+P380+P375P405P420P501P261P270P271P301+P317P319P330P403+P233 |
| Contents | |||
|---|---|---|---|
| Section 2 | Hazards Identification | Section 4 | First-Aid Measures |
| Section 5 | Fire-Fighting Measures | Section 6 | Accidental Release Measures |
| Section 7 | Handling and Storage | Section 8 | Exposure Controls / Personal Protection |
| Section 9 | Physical and Chemical Properties | Section 10 | Stability and Reactivity |
| Section 11 | Toxicological Information | Section 12 | Ecological Information |
| Section 13 | Disposal Considerations | Section 14 | Transport Information |
H271 (48.8%): May cause fire or explosion; strong Oxidizer [Danger Oxidizing liquids; Oxidizing solids]
H272 (51.2%): May intensify fire; oxidizer [Danger Oxidizing liquids; Oxidizing solids]
H314 (81.8%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]
P210, P220, P260, P264, P280, P283, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P306+P360, P316, P321, P363, P370+P378, P371+P380+P375, P405, P420, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 121 reports by companies from 4 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.
H272 (100%): May intensify fire; oxidizer [Danger Oxidizing liquids; Oxidizing solids]
P210, P220, P280, P370+P378, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 100 reports by companies from 1 notifications to the ECHA C&L Inventory.
H302: Harmful if swallowed [Warning Acute toxicity, oral]
H314: Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]
H335: May cause respiratory irritation [Warning Specific target organ toxicity, single exposure; Respiratory tract irritation]
P260, P261, P264, P270, P271, P280, P301+P317, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P316, P319, P321, P330, P363, P403+P233, P405, and P501 (click each P-code to see the statement)
Excerpt from ERG Guide 140 [Oxidizers]:
Refer to the "General First Aid" section. Specific First Aid: Contaminated clothing may be a fire risk when dry. (ERG, 2024)
General First Aid:
· Call 911 or emergency medical service.
· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.
· Move victim to fresh air if it can be done safely.
· Administer oxygen if breathing is difficult.
· If victim is not breathing:
-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.
-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).
-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.
· Remove and isolate contaminated clothing and shoes.
· For minor skin contact, avoid spreading material on unaffected skin.
· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.
· For severe burns, immediate medical attention is required.
· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.
· Keep victim calm and warm.
· Keep victim under observation.
· For further assistance, contact your local Poison Control Center.
· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.
Specific First Aid:
· Contaminated clothing may be a fire risk when dry.
In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.
Excerpt from ERG Guide 140 [Oxidizers]:
SMALL FIRE: Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.
LARGE FIRE: Flood fire area with water from a distance. Do not move cargo or vehicle if cargo has been exposed to heat. If it can be done safely, move undamaged containers away from the area around the fire.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: For ammonium nitrate products: Do not fight cargo fire. Withdraw, evacuate and isolate area for at least 1600 meters (1 mile). Treat as an explosive (ERG Guide 112). Do not enter area for 24 hours or until expert advice has been provided. Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
Personnel protection: ... Wear positive pressure self-contained breathing apparatus when fighting fires involving this material.
If material on fire or involved in fire: Flood with water. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.
Evacuation: If fire becomes uncontrollable -- consider evacuation of one-half (1/2) mile radius.
Will decompose violently in or near a fire.
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· Keep unauthorized personnel away.
· Stay upwind, uphill and/or upstream.
· Ventilate closed spaces before entering, but only if properly trained and equipped.
· Keep combustibles (wood, paper, oil, etc.) away from spilled material.
· Do not touch damaged containers or spilled material unless wearing appropriate protective clothing.
· Stop leak if you can do it without risk.
· Do not get water inside containers.
Small Dry Spill
· With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.
Small Liquid Spill
· Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal.
Large Spill
· Dike far ahead of liquid spill for later disposal.
Excerpt from ERG Guide 140 [Oxidizers]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. If ammonium nitrate products are in a tank, rail car or truck and involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, initiate evacuation including emergency responders for 1600 meters (1 mile) in all directions. (ERG, 2024)
Immediate precautionary measure
· Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
· Consider initial downwind evacuation for at least 100 meters (330 feet).
· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.
· If ammonium nitrate products are in a tank, rail car or truck and involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, initiate evacuation including emergency responders for 1600 meters (1 mile) in all directions.
SRP: The most favorable course of action is to use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination. Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in soil or water; effects on animal and plant life; and conformance with environmental and public health regulations.
SRP: The scientific literature for the use of contact lenses by industrial workers is inconsistent. The benefits or detrimental effects of wearing contact lenses depend not only upon the substance, but also on factors including the form of the substance, characteristics and duration of the exposure, the uses of other eye protection equipment, and the hygiene of the lenses. However, there may be individual substances whose irritating or corrosive properties are such that the wearing of contact lenses would be harmful to the eye. In those specific cases, contact lenses should not be worn. In any event, the usual eye protection equipment should be worn even when contact lenses are in place.
Personnel protection: Avoid breathing dusts. ... Do not handle broken packages unless wearing appropriate personal protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water. ...
If material not on fire and not involved in fire: Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers.
Excerpt from ERG Guide 140 [Oxidizers]:
Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Do not get water inside containers.
SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.
SMALL LIQUID SPILL: Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal.
LARGE SPILL: Dike far ahead of liquid spill for later disposal. (ERG, 2024)
· Wear positive pressure self-contained breathing apparatus (SCBA).
· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.
· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.
Small Fire
· Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.
Large Fire
· Flood fire area with water from a distance.
· Do not move cargo or vehicle if cargo has been exposed to heat.
· If it can be done safely, move undamaged containers away from the area around the fire.
Fire Involving Tanks, Rail Tank Cars or Highway Tanks
· For ammonium nitrate products: Do not fight cargo fire. Withdraw, evacuate and isolate area for at least 1600 meters (1 mile). Treat as an explosive (GUIDE 112). Do not enter area for 24 hours or until expert advice has been provided.
· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.
· Cool containers with flooding quantities of water until well after fire is out.
· ALWAYS stay away from tanks in direct contact with flames.
· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.
Excerpt from ERG Guide 140 [Oxidizers]:
Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
Personnel protection: ... Wear appropriate chemical protective gloves, boots and goggles.
Magnesium peroxide appears as a white powder. Noncombustible but accelerates the burning of combustible material, if the combustible material is finely divided the mixture may be explosive. Mixtures of combustible material and the peroxide can be ignited by friction or contact with moisture. Used in medicine, and as a bleaching agent.
White cubic crystals
White powder
Odorless
Tasteless
100 °C (decomposes)
Soluble in dilute acid solutions with formation of hydrogen peroxide
Insoluble in water and gradually decomposed by it with liberation of oxygen
Approximately 3.0 g/cu cm
A powerful oxidizing material
Dangerous fire risk, reacts with acidic materials and moisture
When strongly heated loses all the peroxide oxygen
Insoluble in water and slowly decomposed by water, liberating oxygen.
Salts, Basic
Oxidizing Agents, Strong
Strong Oxidizing Agent
Mixtures of combustible material and the peroxide can be ignited with friction or moisture. Water gradually decomposes it liberating oxygen, with dilute acids it forms hydrogen peroxide, when strongly heated it losses all peroxide oxygen [Merck 11th ed. 1989].
Mixtures of combustible material and the peroxide can be ignited by friction or contact with moisture.
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Magnesium and Related Compounds/
Basic treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary ... . Monitor for shock and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool ... . /Magnesium and Related Compounds/
Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious, has severe pulmonary edema, or is in severe respiratory distress. Positive-pressure ventilation techniques with a bag valve mask device may be beneficial. Consider drug therapy for pulmonary edema ... . Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start IV administration of D5W /SRP: "To keep open", minimal flow rate/. Use 0.9% saline (NS) or lactated Ringer's (LR) if signs of hypovolemia are present. For hypotension with signs of hypovolemia, administer fluid cautiously. Consider vasopressors if patient is hypotensive with a normal fluid volume. Watch for signs of fluid overload ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Magnesium and Related Compounds/
/OTHER TOXICITY INFORMATION/ Microporous filters containing MgO2 were shown to be effective in the removal and inactivation of bacteria and viruses from tap water. Pseudomonas aeruginosa, P. cepacia and Escherichia coli collected by the filters were found to rapidly decrease in numbers to undetectable levels within 24 hours. In contrast, the same bacteria collected on identical filters not containing MgO2, either rapidly increased in numbers or their numbers remained unchanged. Poliovirus type 1, Echovirus type 1, Reovirus type 3 and Rotavirus SA-11 were found to readily adsorb to the filters. The numbers of viruses which could be recovered from the MgO2 containing filters decreased rapidly with time as compared to control filters. No significant inactivation of bacteria or viruses occurred in tap water passed through the filters, strongly suggesting that the microorganisms were being inactivated while adsorbed to the filters and not by substances released by the filters into the water. The filters remained effective even after the passage of large volumes of tap water through small diameter filters and in the presence of raw sewage contaminated tap water. Such filters could potentially be useful for disinfection of water supplies for small community and individual water systems.
/OTHER TOXICITY INFORMATION/ Sulfate-reducing bacteria (SRB), which cause microbiologically influenced material corrosion under anoxic conditions, form one of the major groups of microorganisms responsible for the generation of hydrogen sulfide. In this study, which is aimed at reducing the presence of SRB, a novel alternative approach involving the addition of magnesium peroxide (MgO2) compounds involving the use of reagent-grade MgO2 and a commercial product (ORC) was evaluated as a means of inhibiting SRB in laboratory batch columns. Different concentrations of MgO2 were added in the columns when black sulfide sediment had appeared in the columns. The experimental results showed that MgO2 is able to inhibit biogenic sulfide. The number of SRB, the sulfide concentration and the sulfate reducing rate (SRR) were decreased. ORC trade mark as an additive was able to decrease more effectively the concentration of sulfide in water and the SRB-control effect was maintained over a longer time period when ORCtrade mark was used. The level of oxidation-reduction potential (ORP), which has a linear relationship to the sulfide/sulfate ratio, is a good indicator of SRB activity. As determined by fluorescence in-situ hybridization (FISH), most SRB growth was inhibited under increasing amounts of added MgO2. The concentration of sulfide reflected the abundance of the SRB. Utilization of organic matter greater than the theoretical SRB utilization rate indicated that facultative heterotrophs became dominant after MgO2 was added. The results of this study could supply the useful information for further study on evaluating the solution to biocorrosion problems in practical situations.
NIOSH (NOES Survey 1981-1983) has statistically estimated that 1,426 workers (12 of these are female) are potentially exposed to manganese peroxide in the US(1).
/OTHER TOXICITY INFORMATION/ Microporous filters containing MgO2 were shown to be effective in the removal and inactivation of bacteria and viruses from tap water. Pseudomonas aeruginosa, P. cepacia and Escherichia coli collected by the filters were found to rapidly decrease in numbers to undetectable levels within 24 hours. In contrast, the same bacteria collected on identical filters not containing MgO2, either rapidly increased in numbers or their numbers remained unchanged. Poliovirus type 1, Echovirus type 1, Reovirus type 3 and Rotavirus SA-11 were found to readily adsorb to the filters. The numbers of viruses which could be recovered from the MgO2 containing filters decreased rapidly with time as compared to control filters. No significant inactivation of bacteria or viruses occurred in tap water passed through the filters, strongly suggesting that the microorganisms were being inactivated while adsorbed to the filters and not by substances released by the filters into the water. The filters remained effective even after the passage of large volumes of tap water through small diameter filters and in the presence of raw sewage contaminated tap water. Such filters could potentially be useful for disinfection of water supplies for small community and individual water systems.
/OTHER TOXICITY INFORMATION/ Sulfate-reducing bacteria (SRB), which cause microbiologically influenced material corrosion under anoxic conditions, form one of the major groups of microorganisms responsible for the generation of hydrogen sulfide. In this study, which is aimed at reducing the presence of SRB, a novel alternative approach involving the addition of magnesium peroxide (MgO2) compounds involving the use of reagent-grade MgO2 and a commercial product (ORC) was evaluated as a means of inhibiting SRB in laboratory batch columns. Different concentrations of MgO2 were added in the columns when black sulfide sediment had appeared in the columns. The experimental results showed that MgO2 is able to inhibit biogenic sulfide. The number of SRB, the sulfide concentration and the sulfate reducing rate (SRR) were decreased. ORC trade mark as an additive was able to decrease more effectively the concentration of sulfide in water and the SRB-control effect was maintained over a longer time period when ORCtrade mark was used. The level of oxidation-reduction potential (ORP), which has a linear relationship to the sulfide/sulfate ratio, is a good indicator of SRB activity. As determined by fluorescence in-situ hybridization (FISH), most SRB growth was inhibited under increasing amounts of added MgO2. The concentration of sulfide reflected the abundance of the SRB. Utilization of organic matter greater than the theoretical SRB utilization rate indicated that facultative heterotrophs became dominant after MgO2 was added. The results of this study could supply the useful information for further study on evaluating the solution to biocorrosion problems in practical situations.
NIOSH (NOES Survey 1981-1983) has statistically estimated that 1,426 workers (12 of these are female) are potentially exposed to manganese peroxide in the US(1).
SRP: The most favorable course of action is to use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination. Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in soil or water; effects on animal and plant life; and conformance with environmental and public health regulations.
/GUIDE 140: OXIDIZERS/ Fire or Explosion: These substances will accelerate burning when involved in a fire. Some may decompose explosively when heated or involved in a fire. May explode from heat or contamination. Some will react explosively with hydrocarbons (fuels). May ignite combustibles (wood, paper, oil, clothing, etc.). Containers may explode when heated. Runoff may create fire or explosion hazard.
/GUIDE 140: OXIDIZERS/ Health: Inhalation, ingestion or contact (skin, eyes) with vapors or substance may cause severe injury, burns or death. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause pollution.
/GUIDE 140: OXIDIZERS/ Public Safety: CALL Emergency Response Telephone Number ... As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. Keep unauthorized personnel away. Stay upwind. Keep out of low areas. Ventilate closed spaces before entering.
/GUIDE 140: OXIDIZERS/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing will only provide limited protection.
For more DOT Emergency Guidelines (Complete) data for Magnesium peroxide (8 total), please visit the HSDB record page.
UN 1476; Magnesium peroxide
Oxidizer