English Safety Data Sheet Database 中文版 MSDS

Peroxydicarbonic acid, C,C'-bis(2-ethylhexyl) ester

CAS No. 16111-62-9 | PubChem CID 85963
Section 1. Identification
Chemical NamePeroxydicarbonic acid, C,C'-bis(2-ethylhexyl) ester CAS No.16111-62-9
Synonymsbis(2-ethylhexyl)peroxydicarbonate; di-(2-ethylhexyl)peroxydicarbonate Chinese Name过氧化二碳酸二(2-乙基己基)酯
Molecular FormulaC18H34O6 Molecular Weight346.459
UN No.3113 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS02 · Flammable GHS07 · Irritant
Hazard Statements H242H302H315H317H319
Precautionary Statements P210P234P235P240P261P264P264+P265P270P272P280P301+P317P302+P352P305+P351+P338P321P330P332+P317P333+P317P337+P317P362+P364P370+P378P403P410P411P420P501

Section 2. Hazards Identification

H242 (100%): Heating may cause a fire [Danger Self-reactive substances and mixtures; Organic peroxides]

H302 (18.6%): Harmful if swallowed [Warning Acute toxicity, oral]

H315 (100%): Causes skin irritation [Warning Skin corrosion/irritation]

H317 (100%): May cause an allergic skin reaction [Warning Sensitization, Skin]

H319 (98.9%): Causes serious eye irritation [Warning Serious eye damage/eye irritation]

P210, P234, P235, P240, P261, P264, P264+P265, P270, P272, P280, P301+P317, P302+P352, P305+P351+P338, P321, P330, P332+P317, P333+P317, P337+P317, P362+P364, P370+P378, P403, P410, P411, P420, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 559 reports by companies from 4 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]:

Refer to the "General First Aid" section. Specific First Aid: Contaminated clothing may be a fire risk when dry. (ERG, 2024)

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]:

The temperature of the substance must be maintained at or below the "Control Temperature" at all times.

SMALL FIRE: Water spray or fog is preferred; if water not available use dry chemical, CO2 or regular foam.

LARGE FIRE: Flood fire area with water from a distance. Use water spray or fog; avoid aiming straight or solid streams directly onto the product. Do not move cargo or vehicle if cargo has been exposed to heat. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. BEWARE OF POSSIBLE CONTAINER EXPLOSION. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

Section 6. Accidental Release Measures

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

LARGE SPILL: Consider initial evacuation for at least 250 meters (800 feet) in all directions.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Section 7. Handling and Storage

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]:

DO NOT allow the substance to warm up. Use a coolant agent such as dry ice or ice (wear thermal protective gloves). If this is not possible or none can be obtained, evacuate the area immediately. ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch or walk through spilled material. Stop leak if you can do it without risk.

SMALL SPILL: Pick up with inert, damp, non-combustible material using clean, non-sparking tools and place into loosely covered plastic containers for later disposal.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Prevent entry into waterways, sewers, basements or confined areas. DO NOT CLEAN-UP OR DISPOSE OF, EXCEPT UNDER SUPERVISION OF A SPECIALIST. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

This liquid peroxide is particularly sensitive to temperature rises. Above a given "Control Temperature" they decompose violently. They are generally stored or transported in a solvent slurry.

Liquid; CBI

Section 10. Stability and Reactivity

No rapid reaction with air. No rapid reaction with water.

Peroxides, Organic

Explosive

Strong Oxidizing Agent

DI-(2-ETHYLHEXYL) PEROXYDICARBONATE decomposes violently or explosively at temperatures 0-10 °C. owing to self-accelerating exothermic decomposition; Several explosions were due to shock, heat or friction; amines and certain metals can cause accelerated decomposition [Bretherick, 1979 p. 156], Danger of explosion when dry

Section 14. Transport Information

Organic Peroxide

Source: PubChem CID 85963 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:42:46.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.