English Safety Data Sheet Database 中文版 MSDS

zinc permanganate

CAS No. 23414-72-4 | PubChem CID 31896
Section 1. Identification
Chemical Namezinc permanganate CAS No.23414-72-4
Synonyms Chinese Name高锰酸锌
Molecular Formula(Z_n(MnO_1)_2) Molecular Weight303.25
UN No.1515 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS03 · Oxidizer GHS08 · Health Hazard
Hazard Statements H272H372
Precautionary Statements P210P220P260P264P270P280P319P370+P378P501

Section 2. Hazards Identification

H272: May intensify fire; oxidizer [Danger Oxidizing liquids; Oxidizing solids]

H372: Causes damage to organs through prolonged or repeated exposure [Danger Specific target organ toxicity, repeated exposure]

P210, P220, P260, P264, P270, P280, P319, P370+P378, and P501 (click each P-code to see the statement)

Section 4. First-Aid Measures

Excerpt from ERG Guide 140 [Oxidizers]:

Refer to the "General First Aid" section. Specific First Aid: Contaminated clothing may be a fire risk when dry. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· Contaminated clothing may be a fire risk when dry.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 140 [Oxidizers]:

SMALL FIRE: Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.

LARGE FIRE: Flood fire area with water from a distance. Do not move cargo or vehicle if cargo has been exposed to heat. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: For ammonium nitrate products: Do not fight cargo fire. Withdraw, evacuate and isolate area for at least 1600 meters (1 mile). Treat as an explosive (ERG Guide 112). Do not enter area for 24 hours or until expert advice has been provided. Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

If material on fire or involved in fire: Flood with water. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.

Personnel protection: ... Wear self-contained breathing apparatus when fighting fires involving this material.

If fire becomes uncontrollable, consider evacuation of one-half mile radius.

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· Keep combustibles (wood, paper, oil, etc.) away from spilled material.

· Do not touch damaged containers or spilled material unless wearing appropriate protective clothing.

· Stop leak if you can do it without risk.

· Do not get water inside containers.

Small Dry Spill

· With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.

Small Liquid Spill

· Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal.

Large Spill

· Dike far ahead of liquid spill for later disposal.

Excerpt from ERG Guide 140 [Oxidizers]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. If ammonium nitrate products are in a tank, rail car or truck and involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, initiate evacuation including emergency responders for 1600 meters (1 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

· Consider initial downwind evacuation for at least 100 meters (330 feet).

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

· If ammonium nitrate products are in a tank, rail car or truck and involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, initiate evacuation including emergency responders for 1600 meters (1 mile) in all directions.

SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices.

Personnel protection: Avoid breathing dusts. ... Do not handle broken packages unless wearing appropriate personal protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water. ...

... If the stopper of a bottle containing ... /zinc permanganate/ becomes stuck, the bottle should be wrapped in a cloth before removal of the stopper is attempted.

If material not on fire and not involved in fire: Avoid breathing dusts. Do not handle broken packages without protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water.

SRP: Local exhaust ventilation should be applied wherever there is an incidence of point source emissions or dispersion of regulated contaminants in the work area. Ventilation control of the contaminant as close to its point of generation is both the most economical and safest method to minimize personnel exposure to airborne contaminants.

WHEN USING WITH STRONG ACIDS TO DESTROY ORGANIC MATTER, PERFORM REACTION BEHIND SAFETY BARRIER. /PERMANGANATES/

Section 7. Handling and Storage

Excerpt from ERG Guide 140 [Oxidizers]:

Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Do not get water inside containers.

SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.

SMALL LIQUID SPILL: Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. (ERG, 2024)

KEEP WELL CLOSED & PROTECTED FROM LIGHT.

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

0.2 [mg/m3], as Mn (inhalable fraction), 0.02 mg/m3, as Mn (respirable fraction), 0.1 mg/m3, as Zn (respirable fraction), 2 mg/m3 (inhalable fraction)[German Research Foundation (DFG)]

500 mg/cu m /Manganese compounds and fume (as Mn)/

0.02 [mg/m3], as Mn (respirable fraction), 0.1 mg/m3, as Mn (inhalable fraction)

8 hr Time Weighted Avg: 0.2 mg/cu m /Manganese and inorganic compounds, as Mn/

Excursion Limit Recommendation: Excursions in worker exposure levels may exceed 3 times the TLV-TWA for no more than a total of 30 minutes during a work day, and under no circumstances should they exceed 5 times the TLV-TWA, provided that the TLV-TWA is not exceeded. /Manganese and inorganic compounds, as Mn/

Chronic Inhalation: 0.0003 mg/m3 (Manganese) (L134)

Intermediate Oral: 0.3 mg/kg/day (Zinc) (L134)

Chronic Oral: 0.3 mg/kg/day (Zinc) (L134)

Small Fire

· Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.

Large Fire

· Flood fire area with water from a distance.

· Do not move cargo or vehicle if cargo has been exposed to heat.

· If it can be done safely, move undamaged containers away from the area around the fire.

Fire Involving Tanks, Rail Tank Cars or Highway Tanks

· For ammonium nitrate products: Do not fight cargo fire. Withdraw, evacuate and isolate area for at least 1600 meters (1 mile). Treat as an explosive (GUIDE 112). Do not enter area for 24 hours or until expert advice has been provided.

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Cool containers with flooding quantities of water until well after fire is out.

· ALWAYS stay away from tanks in direct contact with flames.

· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.

Excerpt from ERG Guide 140 [Oxidizers]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

Zinc permanganate appears as a purplish colored crystalline solid. Noncombustible but accelerates burning of combustible material. Explosion hazard if the combustible material is finely divided. Contact with liquid combustible materials may result in spontaneous ignition. Contact with sulfuric acid may result in fires or explosions.

Purplish to black deliquescent crystals; [HSDB]

Purplish colored crystalline solid

Black-crystals, solution looks purple

Dec @ 90 - 105 °C

Solubility: 33.3 g/100 cc cold water /Hexahydrate/

Very soluble in water, deliquescent

2.45 g/cu cm

Black crystals, solutions look purple; rhombic; density 2.45 g/cu m; decomposes 90-105 °C /Hexahydrate/

Decomp on exposure to light and air /Hexahydrate/

When heated to decomp ... emits toxic fumes of /zinc oxide/.

Hydroscopic; decomposes on exposure to light and air; soluble in water and acids; decomposes in alcohol. /Hexahydrate/

Violet-brown or almost black crystals /Hexahydrate/

Metals -> Metals, Inorganic Compounds

Section 10. Stability and Reactivity

Soluble in water.

Oxidizing Agents, Strong

Strong Oxidizing Agent

Acetic acid or acetic anhydride can explode with permanganates if not kept cold [Von Schwartz 1918. p. 34]. Explosions can occur when permanganates treated with sulfuric acid come in contact with benzene, carbon disulfide, diethyl ether, ethyl alcohol, petroleum, or organic matter.

Incompatible with iodides, reducing agents ... .

Solid zinc permanganate ... /reacts/ violently with many classes of organic cmpd.

An explosion involved contact of ... /zinc/ permanganate with cellulose.

DANGEROUS FIRE RISK IN CONTACT WITH ORGANIC MATERIALS. /HEXAHYDRATE/

For more Hazardous Reactivities and Incompatibilities (Complete) data for ZINC PERMANGANATE (9 total), please visit the HSDB record page.

Section 11. Toxicological Information

Manganese is a cellular toxicant that can impair transport systems, enzyme activities, and receptor functions. It primarily targets the central nervous system, particularily the globus pallidus of the basal ganglia. It is believed that the manganese ion, Mn(II), enhances the autoxidation or turnover of various intracellular catecholamines, leading to increased production of free radicals, reactive oxygen species, and other cytotoxic metabolites, along with a depletion of cellular antioxidant defense mechanisms, leading to oxidative damage and selective destruction of dopaminergic neurons. In addition to dopamine, manganese is thought to perturbations other neurotransmitters, such as GABA and glutamate. In order to produce oxidative damage, manganese must first overwhelm the antioxidant enzyme manganese superoxide dismutase. The neurotoxicity of Mn(II) has also been linked to its ability to substitute for Ca(II) under physiological conditions. It can enter mitochondria via the calcium uniporter and inhibit mitochondrial oxidative phosphorylation. It may also inhibit the efflux of Ca(II), which can result in a loss of mitochondrial membrane integrity. Mn(II) has been shown to inhibit mitochondrial aconitase activity to a significant level, altering amino acid metabolism and cellular iron homeostasis. Anaemia results from the excessive absorption of zinc suppressing copper and iron absorption, most likely through competitive binding of intestinal mucosal cells. Unbalanced levels of copper and zinc binding to Cu,Zn-superoxide dismutase has been linked to amyotrophic lateral sclerosis (ALS). Stomach acid dissolves metallic zinc to give corrosive zinc chloride, which can cause damage to the stomach lining. Metal fume fever is thought to be an immune response to inhaled zinc. (L48, L49, A49, L228)

No indication of carcinogenicity to humans (not listed by IARC).

Manganese mainly affects the nervous system and may cause behavioral changes and other nervous system effects, which include movements that may become slow and clumsy. This combination of symptoms when sufficiently severe is referred to as “manganism”. (L228)

Oral (L49) ; inhalation (L49) ; dermal (L49)

Neurotoxin - Parkinsonism

Occupational hepatotoxin - Secondary hepatotoxins: the potential for toxic effect in the occupational setting is based on cases of poisoning by human ingestion or animal experimentation.

Methemoglobinemia - The presence of increased methemoglobin in the blood; the compound is classified as secondary toxic effect

Dermatotoxin - Skin burns.

Zinc poisoning is treated symptomatically, often by administering fluids such as water or milk, or with gastric lavage. (L49)

Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary ... . Monitor for shock and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool ... . /Manganese and related compounds/

Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious or in severe respiratory distress. Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start an IV with D5W /SRP: "To keep open", minimal flow rate/. Use lactated Ringer's if signs of hypovolemia are present. Consider drug therapy for pulmonary edema ... . For hypotension with signs of hypovolemia, administer fluid cautiously. Consider vasopressors for hypotension with a normal fluid volume. Watch for signs of fluid overload ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Manganese and related compounds/

PERMANGANATE ... OXIDIZES GASTRIC MUCOSAL CELLS. /PERMANGANATE/

MOST BACTERIA ARE KILLED WITHIN 1 HR BY PERMANGANATES IN DILUTION OF 1:10,000, BUT SOME MICROORGANISMS SURVIVE EXPOSURE TO MUCH HIGHER CONCN. GERMICIDAL EFFICIENCY ... IS GREATLY REDUCED IN PRESENCE OF ORG MATTER. /PERMANGANATES/

Section 13. Disposal Considerations

SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices.

Section 14. Transport Information

/GUIDE 140: OXIDIZERS/ Fire or Explosion: These substances will accelerate burning when involved in a fire. Some may decompose explosively when heated or involved in a fire. May explode from heat or contamination. Some will react explosively with hydrocarbons (fuels). May ignite combustibles (wood, paper, oil, clothing, etc.). Containers may explode when heated. Runoff may create fire or explosion hazard.

/GUIDE 140: OXIDIZERS/ Health: Inhalation, ingestion or contact (skin, eyes) with vapors or substance may cause severe injury, burns or death. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause pollution.

/GUIDE 140: OXIDIZERS/ Public Safety: CALL Emergency Response Telephone Number on Shipping Paper first. If Shipping Paper not available or no answer, refer to appropriate telephone number listed on the inside back cover. As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. Keep unauthorized personnel away. Stay upwind. Keep out of low areas. Ventilate closed spaces before entering.

/GUIDE 140: OXIDIZERS/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing will only provide limited protection.

For more DOT Emergency Guidelines (Complete) data for ZINC PERMANGANATE (8 total), please visit the HSDB record page.

UN 1515; Zinc permanganate

IMO 5.1; Zinc permanganate

49 187 57; Zinc permanganate

No person may /transport,/ offer or accept a hazardous material for transportation in commerce unless that person is registered in conformance ... and the hazardous material is properly classed, described, packaged, marked, labeled, and in condition for shipment as required or authorized by ... /the hazardous materials regulations (49 CFR 171-177)./

The International Air Transport Association (IATA) Dangerous Goods Regulations are published by the IATA Dangerous Goods Board pursuant to IATA Resolutions 618 and 619 and constitute a manual of industry carrier regulations to be followed by all IATA Member airlines when transporting hazardous materials.

The International Maritime Dangerous Goods Code lays down basic principles for transporting hazardous chemicals. Detailed recommendations for individual substances and a number of recommendations for good practice are included in the classes dealing with such substances. A general index of technical names has also been compiled. This index should always be consulted when attempting to locate the appropriate procedures to be used when shipping any substance or article.

Oxidizer

Source: PubChem CID 31896 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:42:00.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.