| Section 1. Identification | |||
|---|---|---|---|
| Chemical Name | Tin phosphide (SnP) | CAS No. | 25324-56-5 |
| Synonyms | stannic phosphide; tin phosphide | Chinese Name | 磷化锡 |
| Molecular Formula | SnP | Molecular Weight | 150.6919 |
| UN No. | 1433 | Data Source | PubChem (NIH/NLM) |
| GHS Hazard Classification | |
|---|---|
| Signal Word | WARNING |
| Pictograms | GHS07 · Irritant |
| Hazard Statements | H302H332 |
| Precautionary Statements | P261P264P270P271P301+P317P304+P340P317P330P501 |
| Contents | |||
|---|---|---|---|
| Section 2 | Hazards Identification | Section 4 | First-Aid Measures |
| Section 5 | Fire-Fighting Measures | Section 6 | Accidental Release Measures |
| Section 7 | Handling and Storage | Section 8 | Exposure Controls / Personal Protection |
| Section 9 | Physical and Chemical Properties | Section 10 | Stability and Reactivity |
| Section 14 | Transport Information | ||
H302 (100%): Harmful if swallowed [Warning Acute toxicity, oral]
H332 (100%): Harmful if inhaled [Warning Acute toxicity, inhalation]
P261, P264, P270, P271, P301+P317, P304+P340, P317, P330, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 4 reports by companies from 1 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.
Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:
Refer to the "General First Aid" section. Specific First Aid: In case of contact with substance, wipe from skin immediately; flush skin or eyes with running water for at least 20 minutes. (ERG, 2024)
General First Aid:
· Call 911 or emergency medical service.
· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.
· Move victim to fresh air if it can be done safely.
· Administer oxygen if breathing is difficult.
· If victim is not breathing:
-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.
-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).
-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.
· Remove and isolate contaminated clothing and shoes.
· For minor skin contact, avoid spreading material on unaffected skin.
· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.
· For severe burns, immediate medical attention is required.
· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.
· Keep victim calm and warm.
· Keep victim under observation.
· For further assistance, contact your local Poison Control Center.
· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.
Specific First Aid:
· In case of contact with substance, wipe from skin immediately; flush skin or eyes with running water for at least 20 minutes.
In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.
Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:
DO NOT USE WATER OR FOAM. (FOAM MAY BE USED FOR CHLOROSILANES, SEE BELOW).
SMALL FIRE: Dry chemical, soda ash, lime or sand.
LARGE FIRE: DRY sand, dry chemical, soda ash or lime or withdraw from area and let fire burn. FOR CHLOROSILANES, DO NOT USE WATER; use alcohol-resistant foam; DO NOT USE dry chemicals, soda ash or lime on chlorosilane fires (large or small) as they may release large quantities of hydrogen gas that may explode. If it can be done safely, move undamaged containers away from the area around the fire.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not get water inside containers. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· Keep unauthorized personnel away.
· Stay upwind, uphill and/or upstream.
· Ventilate closed spaces before entering, but only if properly trained and equipped.
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.
· Do not touch or walk through spilled material.
· Stop leak if you can do it without risk.
· DO NOT GET WATER on spilled substance or inside containers.
· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.
· FOR CHLOROSILANES, use alcohol-resistant foam to reduce vapors.
Small Spill
· Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain.
· Dike for later disposal; do not apply water unless directed to do so.
Powder Spill
· Cover powder spill with plastic sheet or tarp to minimize spreading and keep powder dry.
· DO NOT CLEAN-UP OR DISPOSE OF, EXCEPT UNDER SUPERVISION OF A SPECIALIST.
Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Immediate precautionary measure
· Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
· For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
· For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind direction, as necessary.
· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.
Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Do not touch or walk through spilled material. Stop leak if you can do it without risk. DO NOT GET WATER on spilled substance or inside containers. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. FOR CHLOROSILANES, use alcohol-resistant foam to reduce vapors.
SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Dike for later disposal; do not apply water unless directed to do so.
POWDER SPILL: Cover powder spill with plastic sheet or tarp to minimize spreading and keep powder dry. DO NOT CLEAN-UP OR DISPOSE OF, EXCEPT UNDER SUPERVISION OF A SPECIALIST. (ERG, 2024)
· Wear positive pressure self-contained breathing apparatus (SCBA).
· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.
· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.
· DO NOT USE WATER OR FOAM. (FOAM MAY BE USED FOR CHLOROSILANES, SEE BELOW)
Small Fire
· Dry chemical, soda ash, lime or sand.
Large Fire
· DRY sand, dry chemical, soda ash or lime or withdraw from area and let fire burn.
· FOR CHLOROSILANES, DO NOT USE WATER; use alcohol-resistant foam; DO NOT USE dry chemicals, soda ash or lime on chlorosilane fires (large or small) as they may release large quantities of hydrogen gas that may explode.
· If it can be done safely, move undamaged containers away from the area around the fire.
Fire Involving Tanks, Rail Tank Cars or Highway Tanks
· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.
· Cool containers with flooding quantities of water until well after fire is out.
· Do not get water inside containers.
· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.
· ALWAYS stay away from tanks in direct contact with flames.
Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:
Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
Stannic phosphide appears as a silver-white mass or lump solid.
Reactive agents - 2nd degree
Experiments conducted at Argonne showed that no gas is generated upon mixing with water. "Development of the Table of Initial Isolation and Protective Distances for the 2008 Emergency Response Guidebook", ANL/DIS-09-2, D.F. Brown, H.M. Hartmann, W.A. Freeman, and W.D. Haney, Argonne National Laboratory, Argonne, Illinois, June 2009.
Nitrides, Phosphides, Carbides, and Silicides
Strong Reducing Agent
STANNIC PHOSPHIDE is a reducing agent. It slowly generates flammable or noxious gases in contact with water. Reacts quickly upon contact with acids to give the very toxic gas phosphine. Can react vigorously with oxidizing materials.
Dangerous When Wet Poison