English Safety Data Sheet Database 中文版 MSDS

Lithium nitride

CAS No. 26134-62-3 | PubChem CID 520242
Section 1. Identification
Chemical NameLithium nitride CAS No.26134-62-3
Synonymslithiumnitride Chinese Name一氮化锂
Molecular FormulaLiN Molecular Weight34.83
UN No.2806 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS02 · Flammable GHS05 · Corrosive
Hazard Statements H260H314H318
Precautionary Statements P223P231+P232P260P264P264+P265P280P301+P330+P331P302+P335+P334P302+P361+P354P304+P340P305+P354+P338P316P317P321P363P370+P378P402+P404P405P501

Section 2. Hazards Identification

H260 (89.6%): In contact with water releases flammable gases which may ignite spontaneously [Danger Substances and mixtures which in contact with water, emit flammable gases]

H314 (100%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]

H318 (17.1%): Causes serious eye damage [Danger Serious eye damage/eye irritation]

P223, P231+P232, P260, P264, P264+P265, P280, P301+P330+P331, P302+P335+P334, P302+P361+P354, P304+P340, P305+P354+P338, P316, P317, P321, P363, P370+P378, P402+P404, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 240 reports by companies from 5 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:

Refer to the "General First Aid" section. Specific First Aid: In case of contact with substance, wipe from skin immediately; flush skin or eyes with running water for at least 20 minutes. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· In case of contact with substance, wipe from skin immediately; flush skin or eyes with running water for at least 20 minutes.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:

DO NOT USE WATER OR FOAM. (FOAM MAY BE USED FOR CHLOROSILANES, SEE BELOW).

SMALL FIRE: Dry chemical, soda ash, lime or sand.

LARGE FIRE: DRY sand, dry chemical, soda ash or lime or withdraw from area and let fire burn. FOR CHLOROSILANES, DO NOT USE WATER; use alcohol-resistant foam; DO NOT USE dry chemicals, soda ash or lime on chlorosilane fires (large or small) as they may release large quantities of hydrogen gas that may explode. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not get water inside containers. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· Do not touch or walk through spilled material.

· Stop leak if you can do it without risk.

· DO NOT GET WATER on spilled substance or inside containers.

· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.

· FOR CHLOROSILANES, use alcohol-resistant foam to reduce vapors.

Small Spill

· Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain.

· Dike for later disposal; do not apply water unless directed to do so.

Powder Spill

· Cover powder spill with plastic sheet or tarp to minimize spreading and keep powder dry.

· DO NOT CLEAN-UP OR DISPOSE OF, EXCEPT UNDER SUPERVISION OF A SPECIALIST.

NH3 - when spill Lithium nitride into water.

Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 2806 datasheet.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

· For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.

· For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind direction, as necessary.

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

When spilled in water

Small spill:

- ISOLATE in all directions: 30 m (100 ft)

Large spill:

- ISOLATE in all directions: 60 m (200 ft)

- PROTECT people from downwind during DAY time: 0.1 km (0.1 mi)

- PROTECT people from downwind during NIGHT time: 0.2 km (0.2 mi)

- PROTECT people from downwind during DAY time: 0.4 km (0.3 mi)

- PROTECT people from downwind during NIGHT time: 1.6 km (1.0 mi)

Section 7. Handling and Storage

Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Do not touch or walk through spilled material. Stop leak if you can do it without risk. DO NOT GET WATER on spilled substance or inside containers. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. FOR CHLOROSILANES, use alcohol-resistant foam to reduce vapors.

SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Dike for later disposal; do not apply water unless directed to do so.

POWDER SPILL: Cover powder spill with plastic sheet or tarp to minimize spreading and keep powder dry. DO NOT CLEAN-UP OR DISPOSE OF, EXCEPT UNDER SUPERVISION OF A SPECIALIST. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

TIH (Toxic Inhalation Hazard) - Term used to describe gases and volatile liquids that are toxic when inhaled. Some are TIH materials themselves, e.g., chlorine, and some release TIH gases when spilled in water, e.g., chlorosilanes. [ERG 2016].

0.84 [mg/m3]

9.3 [mg/m3]

56 [mg/m3]

· DO NOT USE WATER OR FOAM. (FOAM MAY BE USED FOR CHLOROSILANES, SEE BELOW)

Small Fire

· Dry chemical, soda ash, lime or sand.

Large Fire

· DRY sand, dry chemical, soda ash or lime or withdraw from area and let fire burn.

· FOR CHLOROSILANES, DO NOT USE WATER; use alcohol-resistant foam; DO NOT USE dry chemicals, soda ash or lime on chlorosilane fires (large or small) as they may release large quantities of hydrogen gas that may explode.

· If it can be done safely, move undamaged containers away from the area around the fire.

Fire Involving Tanks, Rail Tank Cars or Highway Tanks

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Cool containers with flooding quantities of water until well after fire is out.

· Do not get water inside containers.

· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.

· ALWAYS stay away from tanks in direct contact with flames.

Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

Lithium nitride appears as a reddish brown powder. Insoluble in most organic solvents. Used in metallurgy and chemical synthesis.

Brownish-red solid or powder; [NJ-HSFS]

1.27 @25 °C

dielectric constant

crystal structure

enthalpy

Gibbs energy

Wyckoff sequence

phase equilibrium

positional coordinate

temperature-composition section

space group

phase diagram

unit cell parameter

melting temperature

charge transfer coefficient

heat capacity

structural phase transition

activation energy of resistivity

transition enthalpy

displacement parameter

band gap energy

structural transition temperature

phase transition

elastic stiffness

Pearson symbol

formation entropy

X-ray diffraction

ionic conductivity

atomic environment

quadrupole coupling

phase stability

transition entropy

particle size

formation enthalpy

electric conductivity

formation energy

quasibinary section

phonon properties

interaxial ratio

Section 10. Stability and Reactivity

Highly flammable. The powder is easily ignited and burns with intense heat. It may ignite spontaneously in moist air. Reacts with water or moisture in the air to generate corrosive lithium hydroxide and toxic ammonia gas. Sufficient heat may be generated during the reaction to ignite nearby combustible materials.

Lithium nitride reacts vigorously with water to generate gaseous NH3. Based on a scenario where the chemical is spilled into an excess of water (at least 5 fold excess of water), half of the maximum theoretical yield of Ammonia gas will be created in 0.04 minutes. Experimental details are in the following: "Development of the Table of Initial Isolation and Protective Distances for the 2008 Emergency Response Guidebook", ANL/DIS-09-2, D.F. Brown, H.M. Hartmann, W.A. Freeman, and W.D. Haney, Argonne National Laboratory, Argonne, Illinois, June 2009.

Bases, Strong

Nitrides, Phosphides, Carbides, and Silicides

Highly Flammable

Strong Reducing Agent

Water-Reactive

Pyrophoric

LITHIUM NITRIDE is a strongly basic reducing agent. Incompatible with oxidizing agents such as atmospheric oxygen. Violently incompatible with acids, particularly oxidizing acids. Reacts violently with copper(I) chloride to produce metallic copper [Mellor, 1940, vol.8, 100]. Reacts exothermically with silicon tetrafluoride, leading to explosion [Chem. Brit., 1979, 15, 282-283].

Section 11. Toxicological Information

Neurotoxin - Other CNS neurotoxin

Nephrotoxin - The chemical is potentially toxic to the kidneys in the occupational setting.

Dermatotoxin - Skin burns.

Toxic Pneumonitis - Inflammation of the lungs induced by inhalation of metal fumes or toxic gases and vapors.

Section 14. Transport Information

Dangerous When Wet

Source: PubChem CID 520242 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 10:04:54.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.