English Safety Data Sheet Database 中文版 MSDS

Pivaloyl chloride

CAS No. 3282-30-2 | PubChem CID 62493
Section 1. Identification
Chemical NamePivaloyl chloride CAS No.3282-30-2
Synonymspivaloylchloride; trimethylacetylchloride Chinese Name三甲基乙酰氯
Molecular FormulaC5HgClO Molecular Weight120.577
UN No.2438 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS02 · Flammable GHS05 · Corrosive GHS06 · Acute Toxic GHS07 · Irritant GHS08 · Health Hazard
Hazard Statements H225H290H302H314H318H330H319H370H371
Precautionary Statements P210P233P234P240P241P242P243P260P264P264+P265P270P271P280P284P301+P317P301+P330+P331P302+P361+P354P303+P361+P353P304+P340P305+P354+P338P316P317P320P321P330P363P370+P378P390P403+P233P403+P235P405P406P501P305+P351+P338P308+P316P337+P317

Section 2. Hazards Identification

This chemical does not meet GHS hazard criteria for 17.8% (52 of 292) of reports.

H225 (81.8%): Highly Flammable liquid and vapor [Danger Flammable liquids]

H290 (58.6%): May be corrosive to metals [Warning Corrosive to Metals]

H302 (81.8%): Harmful if swallowed [Warning Acute toxicity, oral]

H314 (82.2%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]

H318 (59.9%): Causes serious eye damage [Danger Serious eye damage/eye irritation]

H330 (75.7%): Fatal if inhaled [Danger Acute toxicity, inhalation]

P210, P233, P234, P240, P241, P242, P243, P260, P264, P264+P265, P270, P271, P280, P284, P301+P317, P301+P330+P331, P302+P361+P354, P303+P361+P353, P304+P340, P305+P354+P338, P316, P317, P320, P321, P330, P363, P370+P378, P390, P403+P233, P403+P235, P405, P406, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 292 reports by companies from 19 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Reported as not meeting GHS hazard criteria per 52 of 292 reports by companies.

There are 18 notifications provided by 240 of 292 reports by companies with hazard statement code(s).

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

H225: Highly Flammable liquid and vapor [Danger Flammable liquids]

H302: Harmful if swallowed [Warning Acute toxicity, oral]

H314: Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]

H319: Causes serious eye irritation [Warning Serious eye damage/eye irritation]

H330: Fatal if inhaled [Danger Acute toxicity, inhalation]

H370: Causes damage to organs [Danger Specific target organ toxicity, single exposure]

H371: May cause damage to organs [Warning Specific target organ toxicity, single exposure]

P210, P233, P240, P241, P242, P243, P260, P264, P264+P265, P270, P271, P280, P284, P301+P317, P301+P330+P331, P302+P361+P354, P303+P361+P353, P304+P340, P305+P351+P338, P305+P354+P338, P308+P316, P316, P320, P321, P330, P337+P317, P363, P370+P378, P403+P233, P403+P235, P405, and P501 (click each P-code to see the statement)

Section 4. First-Aid Measures

Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

Refer to the "General First Aid" section. Specific First Aid: Wash skin with soap and water. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· Wash skin with soap and water.

· In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient. CAUTION: Methanol (UN1230) will burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.).

SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.

LARGE FIRE: Water spray, fog or alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal. Avoid aiming straight or solid streams directly onto the product.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· All equipment used when handling the product must be grounded.

· Do not touch or walk through spilled material.

· Stop leak if you can do it without risk.

· Prevent entry into waterways, sewers, basements or confined areas.

· A vapor-suppressing foam may be used to reduce vapors.

Small Spill

· Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal.

· Use clean, non-sparking tools to collect absorbed material.

Large Spill

· Dike far ahead of liquid spill for later disposal.

· Water spray may reduce vapor, but may not prevent ignition in closed spaces.

Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 2438 datasheet.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

· For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.

· For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind direction, as necessary.

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

Small spill:

- ISOLATE in all directions: 60 m (200 ft)

Large spill:

- ISOLATE in all directions: 200 m (600 ft)

- PROTECT people from downwind during DAY time: 0.5 km (0.3 mi)

- PROTECT people from downwind during NIGHT time: 1.0 km (0.7 mi)

- PROTECT people from downwind during DAY time: 2.3 km (1.5 mi)

- PROTECT people from downwind during NIGHT time: 3.3 km (2.1 mi)

Section 7. Handling and Storage

Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors.

SMALL SPILL: Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

TIH (Toxic Inhalation Hazard) - Term used to describe gases and volatile liquids that are toxic when inhaled. Some are TIH materials themselves, e.g., chlorine, and some release TIH gases when spilled in water, e.g., chlorosilanes. [ERG 2016].

AEGL 1: Notable discomfort, irritation, or certain asymptomatic non-sensory effects. However, the effects are not disabling and are transient and reversible upon cessation of exposure (Unit: ppm)

AEGL 2: Irreversible or other serious, long-lasting adverse health effects or an impaired ability to escape (Unit: ppm)

AEGL 3: Life-threatening health effects or death (Unit: ppm)

NR = Not recommended due to insufficient data

AEGLs Status: Final

0.015 [ppm]

0.16 [ppm]

0.47 [ppm]

CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient.

CAUTION: Methanol (UN1230) will burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.)

Small Fire

· Dry chemical, CO2, water spray or alcohol-resistant foam.

Large Fire

· Water spray, fog or alcohol-resistant foam.

· If it can be done safely, move undamaged containers away from the area around the fire.

· Dike runoff from fire control for later disposal.

· Avoid aiming straight or solid streams directly onto the product.

Fire Involving Tanks, Rail Tank Cars or Highway Tanks

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Cool containers with flooding quantities of water until well after fire is out.

· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.

· ALWAYS stay away from tanks in direct contact with flames.

· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.

Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

Trimethylacetyl chloride appears as colorless fuming liquid with a pungent odor. Very toxic by inhalation, ingestion or skin absorption. Fumes irritate the eyes and mucous membranes. Corrosive to most metals and tissue.

Colorless to yellow liquid with a pungent odor; [CHEMINFO MSDS]

105-106 °F

107 °C @760 [mm Hg]

1.003 @ 20°C

1.18 [mmHg]

Chemical shift

Lineshape

Nuclear quadrupole resonance spectroscopy

Optical coefficient

Quadrupole coupling

Refractive index

Toxic Gases & Vapors -> Acid Halides

Flammable agents - 3rd degree

Reactive agents - 1st degree

Section 10. Stability and Reactivity

Highly flammable. Fumes in air. The liquid reacts vigorously and exothermically with water to form trimethylacetic acid and corrosive hydrochloric acid; both acids corrode metals and tissue.

Acyl Halides, Sulfonyl Halides, and Chloroformates

Highly Flammable

Water-Reactive

Air-Reactive

TRIMETHYLACETYL CHLORIDE is acidic. Incompatible with bases (including amines), strong oxidizing agents, and alcohols. May react vigorously or explosively if mixed with diisopropyl ether or other ethers in the presence of trace amounts of metal salts [J. Haz. Mat., 1981, 4, 291].

Section 11. Toxicological Information

Dermatotoxin - Skin burns.

Toxic Pneumonitis - Inflammation of the lungs induced by inhalation of metal fumes or toxic gases and vapors.

Section 14. Transport Information

Poison Inhalation Hazard Corrosive Flammable Liquid

Source: PubChem CID 62493 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:55:03.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.