English Safety Data Sheet Database 中文版 MSDS

Perfluoro-2-butene

CAS No. 360-89-4 | PubChem CID 2775851
Section 1. Identification
Chemical NamePerfluoro-2-butene CAS No.360-89-4
Synonymsperfluoro-2-butene; octafluorobut-2-ene Chinese Name八氟-2-丁烯
Molecular FormulaC4F8 Molecular Weight200.03
UN No.2422 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word WARNING
Pictograms GHS04 · Compressed Gas GHS07 · Irritant
Hazard Statements H280H332
Precautionary Statements P261P271P304+P340P317P410+P403

Section 2. Hazards Identification

H280 (100%): Contains gas under pressure; may explode if heated [Warning Gases under pressure]

H332 (100%): Harmful if inhaled [Warning Acute toxicity, inhalation]

P261, P271, P304+P340, P317, and P410+P403 (click each P-code to see the statement)

Aggregated GHS information provided per 115 reports by companies from 2 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:

Refer to the "General First Aid" section. Specific First Aid: In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:

Use extinguishing agent suitable for type of surrounding fire.

SMALL FIRE: Dry chemical or CO2.

LARGE FIRE: Water spray, fog or regular foam. If it can be done safely, move undamaged containers away from the area around the fire. Damaged cylinders should be handled only by specialists.

FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. Some of these materials, if spilled, may evaporate leaving a flammable residue. (ERG, 2024)

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Many gases are heavier than air and will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· Do not touch or walk through spilled material.

· Stop leak if you can do it without risk.

· Do not direct water at spill or source of leak.

· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.

· If possible, turn leaking containers so that gas escapes rather than liquid.

· Prevent entry into waterways, sewers, basements or confined areas.

· Allow substance to evaporate.

· Ventilate the area.

Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 500 meters (1/3 mile).

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area for at least 100 meters (330 feet) in all directions.

Large Spill

· Consider initial downwind evacuation for at least 500 meters (1/3 mile).

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

Section 7. Handling and Storage

Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:

Do not touch or walk through spilled material. Stop leak if you can do it without risk. Do not direct water at spill or source of leak. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. If possible, turn leaking containers so that gas escapes rather than liquid. Prevent entry into waterways, sewers, basements or confined areas. Allow substance to evaporate. Ventilate the area. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

· Use extinguishing agent suitable for type of surrounding fire.

Small Fire

· Dry chemical or CO2.

Large Fire

· Water spray, fog or regular foam.

· If it can be done safely, move undamaged containers away from the area around the fire.

· Damaged cylinders should be handled only by specialists.

Fire Involving Tanks

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Cool containers with flooding quantities of water until well after fire is out.

· Do not direct water at source of leak or safety devices; icing may occur.

· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.

· ALWAYS stay away from tanks in direct contact with flames.

· Some of these materials, if spilled, may evaporate leaving a flammable residue.

Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

Octafluorobut-2-ene appears as a colorless, nonflammable gas. May asphyxiate by the displacement of air. Under prolonged exposure to fire or heat the containers may rupture violently and rocket. Used to make other chemicals.

Colorless gas; [CAMEO]

Diamagnetic susceptibility

Magnetic susceptibility

Other Classes -> Halogenated Aliphatics, Unsaturated

PFAS -> Other/unspecified

PFAS -> OECD Category

Section 10. Stability and Reactivity

No rapid reaction with air. No rapid reaction with water.

Hydrocarbons, Aliphatic Unsaturated

Fluorinated Organic Compounds

OCTAFLUOROBUT-2-ENE may be incompatible with strong oxidizing and reducing agents. Also may be incompatible with many amines, nitrides, azo/diazo compounds, alkali metals, and epoxides.

Section 11. Toxicological Information

Other Poison - Simple Asphyxiant

LC50 (rat) = 81 ppm/4hr

Section 14. Transport Information

Non-Flammable Gas

Source: PubChem CID 2775851 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:32:57.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.