English Safety Data Sheet Database 中文版 MSDS

3-Methoxybutyl acetate

CAS No. 4435-53-4 | PubChem CID 20498
Section 1. Identification
Chemical Name3-Methoxybutyl acetate CAS No.4435-53-4
Synonymsbutoxyl; 3-methoxybutylacetate Chinese Name3-甲氧基乙酸丁酯
Molecular FormulaC7H14O3 Molecular Weight146.1843
UN No. Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word WARNING
Pictograms GHS07 · Irritant
Hazard Statements H336
Precautionary Statements P261P271P304+P340P319P403+P233P405P501

Section 2. Hazards Identification

This chemical does not meet GHS hazard criteria for 59.2% (355 of 600) of all reports.

H336 (35.3%): May cause drowsiness or dizziness [Warning Specific target organ toxicity, single exposure; Narcotic effects]

P261, P271, P304+P340, P319, P403+P233, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 600 reports by companies from 7 notifications to the ECHA C&L Inventory.

Reported as not meeting GHS hazard criteria per 355 of 600 reports by companies.

There are 5 notifications provided by 245 of 600 reports by companies with hazard statement code(s).

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

INHALATION: Call for medical aid. Remove the victim to fresh air. If breathing has stopped, give artificial respiration. If breathing is difficult, give oxygen.

INGESTION: Immediately induce vomiting.

EYES - OR - SKIN: Flush with copious amounts of water for at least 15 minutes. (USCG, 1999)

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]:

CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient. CAUTION: For mixtures containing alcohol or polar solvent, alcohol-resistant foam may be more effective.

SMALL FIRE: Dry chemical, CO2, water spray or regular foam. If regular foam is ineffective or unavailable, use alcohol-resistant foam.

LARGE FIRE: Water spray, fog or regular foam. If regular foam is ineffective or unavailable, use alcohol-resistant foam. Avoid aiming straight or solid streams directly onto the product. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. For petroleum crude oil, do not spray water directly into a breached tank car. This can lead to a dangerous boil over. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

Section 6. Accidental Release Measures

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Section 7. Handling and Storage

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

Self-contained breathing apparatus, rubber boots and heavy rubber gloves. (USCG, 1999)

Section 9. Physical and Chemical Properties

Butoxyl appears as a liquid with an acrid odor. Flash point near 140 °F. Slightly less dense than water. Vapors much heavier than air. May irritate skin, eyes, and mucous membranes.

275 °F at 760 mmHg (USCG, 1999)

170 °F (USCG, 1999)

0.96 (USCG, 1999) - Less dense than water; will float

Flammable agents - 2nd degree

Reactive agents - 1st degree

Section 10. Stability and Reactivity

Flammable. Slightly soluble in water.

Esters, Sulfate Esters, Phosphate Esters, Thiophosphate Esters, and Borate Esters

When heated to decomposition, emits acrid smoke and irritating fumes (USCG, 1999).

3-Methoxy-1-butyl acetate

D: Other compounds that may form peroxides

Section 14. Transport Information

Flammable Liquid

Source: PubChem CID 20498 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:46:23.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.