Section 1. Identification
Chemical Nameallene CAS No.463-49-0
Synonymspropadiene;dimethylenemethane Chinese Name丙二烯
Molecular FormulaC3H4 Molecular Weight40.07
UN No.2200 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS02 · Flammable GHS04 · Compressed Gas
Hazard Statements H220H280
Precautionary Statements P203P210P222P280P377P381P403P410+P403

Section 2. Hazards Identification

This chemical does not meet GHS hazard criteria for 0.3% (1 of 317) of reports.

H220 (87.7%): Extremely flammable gas [Danger Flammable gases]

H280 (99.4%): Contains gas under pressure; may explode if heated [Warning Gases under pressure]

P203, P210, P222, P280, P377, P381, P403, and P410+P403 (click each P-code to see the statement)

Aggregated GHS information provided per 317 reports by companies from 8 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Reported as not meeting GHS hazard criteria per 1 of 317 reports by companies.

There are 7 notifications provided by 316 of 317 reports by companies with hazard statement code(s).

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

Excerpt from ERG Guide 116 [Gases - Flammable (Unstable); polymerization hazard]:

Refer to the "General First Aid" section. Specific First Aid: In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts.

· In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 116 [Gases - Flammable (Unstable); polymerization hazard]:

DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.

SMALL FIRE: Dry chemical or CO2.

LARGE FIRE: Water spray or fog. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Many gases are heavier than air and will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· All equipment used when handling the product must be grounded.

· Stop leak if you can do it without risk.

· Do not touch or walk through spilled material.

· Do not direct water at spill or source of leak.

· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.

· If possible, turn leaking containers so that gas escapes rather than liquid.

· Prevent entry into waterways, sewers, basements or confined areas.

· Isolate area until gas has dispersed.

Excerpt from ERG Guide 116 [Gases - Flammable (Unstable); polymerization hazard]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 800 meters (1/2 mile).

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area for at least 100 meters (330 feet) in all directions.

Large Spill

· Consider initial downwind evacuation for at least 800 meters (1/2 mile).

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions.

Section 7. Handling and Storage

Excerpt from ERG Guide 116 [Gases - Flammable (Unstable); polymerization hazard]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Stop leak if you can do it without risk. Do not touch or walk through spilled material. Do not direct water at spill or source of leak. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. If possible, turn leaking containers so that gas escapes rather than liquid. Prevent entry into waterways, sewers, basements or confined areas. Isolate area until gas has dispersed. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

230 [ppm]

2500 [ppm]

15000 [ppm]

· DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.

Small Fire

· Dry chemical or CO2.

Large Fire

· Water spray or fog.

· If it can be done safely, move undamaged containers away from the area around the fire.

Fire Involving Tanks

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Cool containers with flooding quantities of water until well after fire is out.

· Do not direct water at source of leak or safety devices; icing may occur.

· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.

· ALWAYS stay away from tanks in direct contact with flames.

· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.

Excerpt from ERG Guide 116 [Gases - Flammable (Unstable); polymerization hazard]:

Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

Propadiene, stabilized appears as a colorless flammable gas. May become unstable. Not toxic but asphyxiation may occur because of displacement of oxygen. Under prolonged exposure to fire or heat the containers may rupture violently and rocket.

Colorless gas; [HSDB]

COLORLESS

-34.5 °C @ 760 MM HG

-34.5 °C @760 [mm Hg]

INSOL IN WATER; SOL IN BENZENE, PETROLEUM ETHER

0.677 @25 °C

5430.0 [mmHg]

5990 [mm Hg] @20 °C

UNSTABLE

INDEX OF REFRACTION: 1.4168

CAN BE READILY LIQUIFIED

Dunham energy parameter

Schoenflies notation

Acentric factor

Atomic environment

Boiling point

Bond type

Centrifugal distortion

Chemical bond

Chemical diffusion

Composition

Compressibility

Critical point

Diamagnetic susceptibility

Dielectric constant

Diffusion

Diffusive flux

Dissociation energy

Electric dipole moment

Fusion temperature

Heat capacity

Heat of sublimation

Internuclear distance

Magnetic permeability

Magnetic susceptibility

Melting curve

Melting temperature

Molar mass

Molecular structure

Section 10. Stability and Reactivity

Highly flammable.

Conjugated Dienes

Polymerizable Compounds

Highly Flammable

Polymerizable

The unsaturated aliphatic hydrocarbons, such as PROPADIENE, are generally much more reactive than the alkanes. Strong oxidizers may react vigorously with them. Reducing agents can react exothermically to release gaseous hydrogen. In the presence of various catalysts (such as acids) or initiators, compounds in this class can undergo very exothermic addition polymerization reactions. Many of these compounds undergo autoxidation upon exposure to the air to form explosive peroxides. Violent explosions have occurred at low temperatures in ammonia synthesis gas units. These explosions have been traced to the addition products of dienes and oxides of nitrogen, produced from the interaction of nitrogen oxide and oxygen [Bretherick, 1995].

Section 11. Toxicological Information

Neurotoxin - Acute solvent syndrome

Other Poison - Simple Asphyxiant

Section 14. Transport Information

/GUIDE 116P: GASES - FLAMMABLE (UNSTABLE)/ Fire or Explosion: EXTREMELY FLAMMABLE. Will be easily ignited by heat, sparks or flames. Will form explosive mixtures with air. ... Those substances designated with a "P" may polymerize explosively when heated or involved in a fire. Vapors from liquefied gas are initially heavier than air and spread along ground. Vapors may travel to source of ignition and flash back. Cylinders exposed to fire may vent and release flammable gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket. /Propadiene, inhibited; Propadiene, stabilized/

/GUIDE 116P: GASES - FLAMMABLE (UNSTABLE)/ Health: Vapors may cause dizziness or asphyxiation without warning. Some may be toxic if inhaled at high concentrations. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Fire may produce irritating and/or toxic gases. /Propadiene, inhibited; Propadiene, stabilized/

/GUIDE 116P: GASES - FLAMMABLE (UNSTABLE)/ Public Safety: CALL Emergency Response Telephone Number ... . As an immediate precautionary measure, isolate spill or leak area for at least 100 meters (330 feet) in all directions. Keep unauthorized personnel away. Stay upwind. Many gases are heavier than air and will spread along ground and collect in low or confined areas (sewers, basements, tanks). Keep out of low areas. /Propadiene, inhibited; Propadiene, stabilized/

/GUIDE 116P: GASES - FLAMMABLE (UNSTABLE)/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing will only provide limited protection. /Propadiene, inhibited; Propadiene, stabilized/

For more DOT Emergency Guidelines (Complete) data for PROPADIENE (8 total), please visit the HSDB record page.

2200 116P

UN 2200; Propadiene, stabilized

IMO 2.1; Propadiene, stabilized

No person may /transport,/ offer or accept a hazardous material for transportation in commerce unless that person is registered in conformance ... and the hazardous material is properly classed, described, packaged, marked, labeled, and in condition for shipment as required or authorized by ... /the hazardous materials regulations (49 CFR 171-177)./

The International Air Transport Association (IATA) Dangerous Goods Regulations are published by the IATA Dangerous Goods Board pursuant to IATA Resolutions 618 and 619 and constitute a manual of industry carrier regulations to be followed by all IATA Member airlines when transporting hazardous materials.

The International Maritime Dangerous Goods Code lays down basic principles for transporting hazardous chemicals. Detailed recommendations for individual substances and a number of recommendations for good practice are included in the classes dealing with such substances. A general index of technical names has also been compiled. This index should always be consulted when attempting to locate the appropriate procedures to be used when shipping any substance or article.

Flammable Gas

Source: PubChem CID 10037 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 08:53:04.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.