| Section 1. Identification | |||
|---|---|---|---|
| Chemical Name | acetyl iodide | CAS No. | 507-02-8 |
| Synonyms | ethanoyl iodide | Chinese Name | 乙酰碘 |
| Molecular Formula | C2H3IO | Molecular Weight | 169.9491 |
| UN No. | — | Data Source | PubChem (NIH/NLM) |
| GHS Hazard Classification | |
|---|---|
| Signal Word | DANGER |
| Pictograms | GHS02 · Flammable GHS05 · Corrosive |
| Hazard Statements | H225H290H314H318 |
| Precautionary Statements | P210P233P234P240P241P242P243P260P264P264+P265P280P301+P330+P331P302+P361+P354P303+P361+P353P304+P340P305+P354+P338P316P317P321P363P370+P378P390P403+P235P405P406P501 |
| Contents | |||
|---|---|---|---|
| Section 2 | Hazards Identification | Section 4 | First-Aid Measures |
| Section 5 | Fire-Fighting Measures | Section 6 | Accidental Release Measures |
| Section 7 | Handling and Storage | Section 8 | Exposure Controls / Personal Protection |
| Section 9 | Physical and Chemical Properties | Section 10 | Stability and Reactivity |
| Section 11 | Toxicological Information | Section 14 | Transport Information |
H225 (100%): Highly Flammable liquid and vapor [Danger Flammable liquids]
H290 (100%): May be corrosive to metals [Warning Corrosive to Metals]
H314 (100%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]
H318 (100%): Causes serious eye damage [Danger Serious eye damage/eye irritation]
P210, P233, P234, P240, P241, P242, P243, P260, P264, P264+P265, P280, P301+P330+P331, P302+P361+P354, P303+P361+P353, P304+P340, P305+P354+P338, P316, P317, P321, P363, P370+P378, P390, P403+P235, P405, P406, and P501 (click each P-code to see the statement)
The GHS information provided by 1 company from 1 notification to the ECHA C&L Inventory.
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]:
Refer to the "General First Aid" section. Specific First Aid: For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required. Removal of solidified molten material from skin requires medical assistance. (ERG, 2024)
General First Aid:
· Call 911 or emergency medical service.
· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.
· Move victim to fresh air if it can be done safely.
· Administer oxygen if breathing is difficult.
· If victim is not breathing:
-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.
-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).
-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.
· Remove and isolate contaminated clothing and shoes.
· For minor skin contact, avoid spreading material on unaffected skin.
· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.
· For severe burns, immediate medical attention is required.
· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.
· Keep victim calm and warm.
· Keep victim under observation.
· For further assistance, contact your local Poison Control Center.
· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.
Specific First Aid:
· For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required.
· Removal of solidified molten material from skin requires medical assistance.
In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]:
Note: Most foams will react with the material and release corrosive/toxic gases. CAUTION: For Acetyl bromide (UN1716), use CO2 or dry chemical only.
SMALL FIRE: CO2, dry chemical, dry sand, alcohol-resistant foam.
LARGE FIRE: Water spray, fog or alcohol-resistant foam. FOR CHLOROSILANES, DO NOT USE WATER; use alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Avoid aiming straight or solid streams directly onto the product.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· Keep unauthorized personnel away.
· Stay upwind, uphill and/or upstream.
· Ventilate closed spaces before entering, but only if properly trained and equipped.
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.
· All equipment used when handling the product must be grounded.
· Do not touch damaged containers or spilled material unless wearing appropriate protective clothing.
· Stop leak if you can do it without risk.
· A vapor-suppressing foam may be used to reduce vapors.
· FOR CHLOROSILANES, use alcohol-resistant foam to reduce vapors.
· DO NOT GET WATER on spilled substance or inside containers.
· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.
· Prevent entry into waterways, sewers, basements or confined areas.
Small Spill
· Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain.
· Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal.
HI - when spill Acetyl iodide into water.
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 1898 datasheet.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Immediate precautionary measure
· Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
· For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
· For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind direction, as necessary.
· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.
When spilled in water
Small spill:
- ISOLATE in all directions: 30 m (100 ft)
Large spill:
- PROTECT people from downwind during DAY time: 0.1 km (0.1 mi)
- PROTECT people from downwind during NIGHT time: 0.1 km (0.1 mi)
- PROTECT people from downwind during DAY time: 0.3 km (0.2 mi)
- PROTECT people from downwind during NIGHT time: 0.9 km (0.6 mi)
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. A vapor-suppressing foam may be used to reduce vapors. FOR CHLOROSILANES, use alcohol-resistant foam to reduce vapors. DO NOT GET WATER on spilled substance or inside containers. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Prevent entry into waterways, sewers, basements or confined areas.
SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. (ERG, 2024)
· Wear positive pressure self-contained breathing apparatus (SCBA).
· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.
· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.
TIH (Toxic Inhalation Hazard) - Term used to describe gases and volatile liquids that are toxic when inhaled. Some are TIH materials themselves, e.g., chlorine, and some release TIH gases when spilled in water, e.g., chlorosilanes. [ERG 2016].
· Note: Most foams will react with the material and release corrosive/toxic gases.
CAUTION: For Acetyl bromide (UN1716), use CO2 or dry chemical only.
Small Fire
· CO2, dry chemical, dry sand, alcohol-resistant foam.
Large Fire
· Water spray, fog or alcohol-resistant foam.
· FOR CHLOROSILANES, DO NOT USE WATER; use alcohol-resistant foam.
· If it can be done safely, move undamaged containers away from the area around the fire.
· Avoid aiming straight or solid streams directly onto the product.
Fire Involving Tanks, Rail Tank Cars or Highway Tanks
· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.
· Do not get water inside containers.
· Cool containers with flooding quantities of water until well after fire is out.
· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.
· ALWAYS stay away from tanks in direct contact with flames.
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]:
Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
Acetyl iodide appears as a colorless, fuming liquid with a pungent odor. Soluble in benzene and ether (Merck 11th ed., 1989). Vapors are irritating to the eyes and mucous membranes. Vapor causes pulmonary edema. Corrosive to metals and skin.
Colorless, fuming liquid with a pungent odor that turns brown on contact with air; [CAMEO]
32.4 [mmHg]
Schoenflies notation
Boiling point
Chemical bond
Heat of sublimation
Hindering potential
Internuclear distance
Molecular structure
Moment of inertia
Nuclear quadrupole coupling
Nuclear quadrupole moment
Optical coefficient
Point group
Refractive index
Rotational excitation cross section
Vapor pressure
Vibrational mode frequency
Toxic Gases & Vapors -> Acid Halides
Corrosives
Fumes in air. Turns brown on exposure to air as it reacts exothermically with moisture in the air to give hydrogen Iodide (hydroiodic acid), a strong irritant. Decomposes in water to give acidic products.
Based on a scenario where the chemical is spilled into an excess of water (at least 5 fold excess of water), half of the maximum theoretical yield of Hydrogen Iodide gas will be created in 0.02 minutes. Experimental details are in the following: "Development of the Table of Initial Isolation and Protective Distances for the 2008 Emergency Response Guidebook", ANL/DIS-09-2, D.F. Brown, H.M. Hartmann, W.A. Freeman, and W.D. Haney, Argonne National Laboratory, Argonne, Illinois, June 2009.
Acyl Halides, Sulfonyl Halides, and Chloroformates
Water-Reactive
Air-Reactive
ACETYL IODIDE decomposes exothermically in water or alcohol. Reacts vigorously and exothermically with bases. May react vigorously or explosively if mixed with diisopropyl ether or other ethers in the presence of trace amounts of metal salts [J. Haz. Mat., 1981, 4, 291].
Dermatotoxin - Skin burns.
Toxic Pneumonitis - Inflammation of the lungs induced by inhalation of metal fumes or toxic gases and vapors.
Corrosive