English Safety Data Sheet Database 中文版 MSDS

Furfurylamine

CAS No. 617-89-0 | PubChem CID 3438
Section 1. Identification
Chemical NameFurfurylamine CAS No.617-89-0
Synonyms2-furylmethylamine; 2-furfurylamine Chinese Name糠胺
Molecular FormulaC5H7NO Molecular Weight97.1152
UN No. Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS02 · Flammable GHS05 · Corrosive GHS06 · Acute Toxic GHS07 · Irritant
Hazard Statements H226H301H302H310H311H312H314H332
Precautionary Statements P210P233P240P241P242P243P260P261P262P264P270P271P280P301+P316P301+P317P301+P330+P331P302+P352P302+P361+P354P303+P361+P353P304+P340P305+P354+P338P316P317P321P330P361+P364P362+P364P363P370+P378P403+P235P405P501

Section 2. Hazards Identification

This chemical does not meet GHS hazard criteria for 4.3% (4 of 92) of reports.

H226 (95.7%): Flammable liquid and vapor [Warning Flammable liquids]

H301 (32.6%): Toxic if swallowed [Danger Acute toxicity, oral]

H302 (62%): Harmful if swallowed [Warning Acute toxicity, oral]

H310 (28.3%): Fatal in contact with skin [Danger Acute toxicity, dermal]

H311 (17.4%): Toxic in contact with skin [Danger Acute toxicity, dermal]

H312 (47.8%): Harmful in contact with skin [Warning Acute toxicity, dermal]

H314 (95.7%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]

H332 (30.4%): Harmful if inhaled [Warning Acute toxicity, inhalation]

P210, P233, P240, P241, P242, P243, P260, P261, P262, P264, P270, P271, P280, P301+P316, P301+P317, P301+P330+P331, P302+P352, P302+P361+P354, P303+P361+P353, P304+P340, P305+P354+P338, P316, P317, P321, P330, P361+P364, P362+P364, P363, P370+P378, P403+P235, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 92 reports by companies from 11 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Reported as not meeting GHS hazard criteria per 4 of 92 reports by companies.

There are 10 notifications provided by 88 of 92 reports by companies with hazard statement code(s).

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:

Refer to the "General First Aid" section. Specific First Aid: For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required.

· In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:

Some of these materials may react violently with water.

SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.

LARGE FIRE: Water spray, fog or alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal. Do not get water inside containers.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· All equipment used when handling the product must be grounded.

· Do not touch or walk through spilled material.

· Stop leak if you can do it without risk.

· Prevent entry into waterways, sewers, basements or confined areas.

· A vapor-suppressing foam may be used to reduce vapors.

· Absorb with earth, sand or other non-combustible material.

· For hydrazine, absorb with DRY sand or inert absorbent (vermiculite or absorbent pads).

· Use clean, non-sparking tools to collect absorbed material.

Large Spill

· Dike far ahead of liquid spill for later disposal.

· Water spray may reduce vapor, but may not prevent ignition in closed spaces.

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

· For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.

· For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind direction, as necessary.

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

Section 7. Handling and Storage

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb with earth, sand or other non-combustible material. For hydrazine, absorb with DRY sand or inert absorbent (vermiculite or absorbent pads). Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

· Some of these materials may react violently with water.

Small Fire

· Dry chemical, CO2, water spray or alcohol-resistant foam.

Large Fire

· Water spray, fog or alcohol-resistant foam.

· If it can be done safely, move undamaged containers away from the area around the fire.

· Dike runoff from fire control for later disposal.

· Do not get water inside containers.

Fire Involving Tanks, Rail Tank Cars or Highway Tanks

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Cool containers with flooding quantities of water until well after fire is out.

· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.

· ALWAYS stay away from tanks in direct contact with flames.

· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

Furfurylamine appears as a colorless liquid. About the same density as water. Used as a corrosion inhibitor and to make soldering flux.

Colorless liquid; [CAMEO] Colorless liquid with an amine-like odor; [Alfa Aesar MSDS]

99 °F (NFPA, 2010)

4.73 [mmHg]

Schoenflies notation

Chemical bond

Internuclear distance

Molecular structure

Optical coefficient

Point group

Reaction coordinate

Refractive index

Rotational excitation cross section

Vibrational mode frequency

Nitrogen Compounds -> Other Nitrogen Compounds

Flammable agents - 3rd degree

Section 10. Stability and Reactivity

Highly flammable. Soluble in water.

Amines, Phosphines, and Pyridines

Highly Flammable

Amines, such as FURFURYLAMINE, are chemical bases. They neutralize acids to form salts plus water. These acid-base reactions are exothermic. The amount of heat that is evolved per mole of amine in a neutralization is largely independent of the strength of the amine as a base. Amines may be incompatible with isocyanates, halogenated organics, peroxides, phenols (acidic), epoxides, anhydrides, and acid halides. Flammable gaseous hydrogen is generated by amines in combination with strong reducing agents, such as hydrides.

Section 11. Toxicological Information

Dermatotoxin - Skin burns.

Toxic Pneumonitis - Inflammation of the lungs induced by inhalation of metal fumes or toxic gases and vapors.

LC50 (rat) = 1,300 mg/m3/4hr

Section 14. Transport Information

Flammable Liquid Corrosive

Source: PubChem CID 3438 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:46:32.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.