| Section 1. Identification | |||
|---|---|---|---|
| Chemical Name | valeryl chloride | CAS No. | 638-29-9 |
| Synonyms | pentanoyl chloride | Chinese Name | 戊酰氯 |
| Molecular Formula | C5H9C1O | Molecular Weight | 120.577 |
| UN No. | 2502 | Data Source | PubChem (NIH/NLM) |
| GHS Hazard Classification | |
|---|---|
| Signal Word | DANGER |
| Pictograms | GHS02 · Flammable GHS05 · Corrosive GHS06 · Acute Toxic |
| Hazard Statements | H226H290H314H318H331H412 |
| Precautionary Statements | P210P233P234P240P241P242P243P260P261P264P264+P265P271P273P280P301+P330+P331P302+P361+P354P303+P361+P353P304+P340P305+P354+P338P316P317P321P363P370+P378P390P403+P233P403+P235P405P406P501 |
| Contents | |||
|---|---|---|---|
| Section 2 | Hazards Identification | Section 4 | First-Aid Measures |
| Section 5 | Fire-Fighting Measures | Section 6 | Accidental Release Measures |
| Section 7 | Handling and Storage | Section 8 | Exposure Controls / Personal Protection |
| Section 9 | Physical and Chemical Properties | Section 10 | Stability and Reactivity |
| Section 11 | Toxicological Information | Section 14 | Transport Information |
H226 (100%): Flammable liquid and vapor [Warning Flammable liquids]
H290 (71.9%): May be corrosive to metals [Warning Corrosive to Metals]
H314 (99.4%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]
H318 (71.9%): Causes serious eye damage [Danger Serious eye damage/eye irritation]
H331 (96.2%): Toxic if inhaled [Danger Acute toxicity, inhalation]
H412 (71.9%): Harmful to aquatic life with long lasting effects [Hazardous to the aquatic environment, long-term hazard]
P210, P233, P234, P240, P241, P242, P243, P260, P261, P264, P264+P265, P271, P273, P280, P301+P330+P331, P302+P361+P354, P303+P361+P353, P304+P340, P305+P354+P338, P316, P317, P321, P363, P370+P378, P390, P403+P233, P403+P235, P405, P406, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 160 reports by companies from 10 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.
Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:
Refer to the "General First Aid" section. Specific First Aid: For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)
General First Aid:
· Call 911 or emergency medical service.
· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.
· Move victim to fresh air if it can be done safely.
· Administer oxygen if breathing is difficult.
· If victim is not breathing:
-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.
-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).
-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.
· Remove and isolate contaminated clothing and shoes.
· For minor skin contact, avoid spreading material on unaffected skin.
· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.
· For severe burns, immediate medical attention is required.
· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.
· Keep victim calm and warm.
· Keep victim under observation.
· For further assistance, contact your local Poison Control Center.
· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.
Specific First Aid:
· For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required.
· In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin.
In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.
Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:
Some of these materials may react violently with water.
SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.
LARGE FIRE: Water spray, fog or alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal. Do not get water inside containers.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· Keep unauthorized personnel away.
· Stay upwind, uphill and/or upstream.
· Ventilate closed spaces before entering, but only if properly trained and equipped.
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.
· All equipment used when handling the product must be grounded.
· Do not touch or walk through spilled material.
· Stop leak if you can do it without risk.
· Prevent entry into waterways, sewers, basements or confined areas.
· A vapor-suppressing foam may be used to reduce vapors.
· Absorb with earth, sand or other non-combustible material.
· For hydrazine, absorb with DRY sand or inert absorbent (vermiculite or absorbent pads).
· Use clean, non-sparking tools to collect absorbed material.
Large Spill
· Dike far ahead of liquid spill for later disposal.
· Water spray may reduce vapor, but may not prevent ignition in closed spaces.
Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Immediate precautionary measure
· Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
· For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
· For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind direction, as necessary.
· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.
Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb with earth, sand or other non-combustible material. For hydrazine, absorb with DRY sand or inert absorbent (vermiculite or absorbent pads). Use clean, non-sparking tools to collect absorbed material.
LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
· Wear positive pressure self-contained breathing apparatus (SCBA).
· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.
· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.
· Some of these materials may react violently with water.
Small Fire
· Dry chemical, CO2, water spray or alcohol-resistant foam.
Large Fire
· Water spray, fog or alcohol-resistant foam.
· If it can be done safely, move undamaged containers away from the area around the fire.
· Dike runoff from fire control for later disposal.
· Do not get water inside containers.
Fire Involving Tanks, Rail Tank Cars or Highway Tanks
· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.
· Cool containers with flooding quantities of water until well after fire is out.
· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.
· ALWAYS stay away from tanks in direct contact with flames.
· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.
Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:
Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
Valeryl chloride appears as a colorless fuming liquid with a pungent odor. Fumes irritate the eyes and mucous membranes. Corrosive.
Colorless fuming liquid with a pungent odor; [CAMEO] Colorless to pale yellow liquid with an acrid odor; [Alfa Aesar MSDS]
Boiling point
Diamagnetic susceptibility
Heat of sublimation
Magnetic susceptibility
Optical coefficient
Refractive index
Vapor pressure
Toxic Gases & Vapors -> Acid Halides
Corrosives
Flammable agents - 3rd degree
Reactive agents - 1st degree
Highly flammable. Fumes in air. Reacts exothermically with water to generate hydrochloric and valeric acids, which are corrosive.
Acyl Halides, Sulfonyl Halides, and Chloroformates
Highly Flammable
Water-Reactive
Air-Reactive
VALERYL CHLORIDE is acidic. Incompatible with water, with bases, including amines, and with strong oxidizing agents and alcohols. May react vigorously or explosively if mixed with diisopropyl ether or other ethers in the presence of trace amounts of metal salts [J. Haz. Mat., 1981, 4, 291].
Dermatotoxin - Skin burns.
Toxic Pneumonitis - Inflammation of the lungs induced by inhalation of metal fumes or toxic gases and vapors.
LC50 (rat) = 2,070 mg/m3/4hr
Corrosive Flammable Liquid