| Section 1. Identification | |||
|---|---|---|---|
| Chemical Name | antimonytrifluoride | CAS No. | 7783-56-4 |
| Synonyms | antimony (Ⅲ)flu-oride3321三氟化锑--- | Chinese Name | 三氟化锑 |
| Molecular Formula | SbF3 | Molecular Weight | 178.75 |
| UN No. | 1549 | Data Source | PubChem (NIH/NLM) |
| GHS Hazard Classification | |
|---|---|
| Signal Word | DANGER |
| Pictograms | GHS05 · Corrosive GHS06 · Acute Toxic GHS07 · Irritant GHS08 · Health Hazard GHS09 · Environmental Hazard |
| Hazard Statements | H301H311H331H411H351H302H315H319H335H372H314H318H401 |
| Precautionary Statements | P261P262P264P270P271P273P280P301+P316P302+P352P304+P340P316P321P330P361+P364P391P403+P233P405P501P203P318P260P264+P265P301+P317P305+P351+P338P319P332+P317P337+P317P362+P364P301+P330+P331P302+P361+P354P305+P354+P338P317P363 |
| Contents | |||
|---|---|---|---|
| Section 2 | Hazards Identification | Section 4 | First-Aid Measures |
| Section 5 | Fire-Fighting Measures | Section 6 | Accidental Release Measures |
| Section 7 | Handling and Storage | Section 8 | Exposure Controls / Personal Protection |
| Section 9 | Physical and Chemical Properties | Section 10 | Stability and Reactivity |
| Section 11 | Toxicological Information | Section 13 | Disposal Considerations |
| Section 14 | Transport Information | ||
H301: Toxic if swallowed [Danger Acute toxicity, oral]
H311: Toxic in contact with skin [Danger Acute toxicity, dermal]
H331: Toxic if inhaled [Danger Acute toxicity, inhalation]
H411: Toxic to aquatic life with long lasting effects [Hazardous to the aquatic environment, long-term hazard]
P261, P262, P264, P270, P271, P273, P280, P301+P316, P302+P352, P304+P340, P316, P321, P330, P361+P364, P391, P403+P233, P405, and P501 (click each P-code to see the statement)
H301+H311+H331 (31.9%): Toxic if swallowed, in contact with skin or if inhaled [Danger Acute toxicity, oral; acute toxicity, dermal; acute toxicity, inhalation]
H301 (100%): Toxic if swallowed [Danger Acute toxicity, oral]
H311 (100%): Toxic in contact with skin [Danger Acute toxicity, dermal]
H331 (100%): Toxic if inhaled [Danger Acute toxicity, inhalation]
H351 (33.3%): Suspected of causing cancer [Warning Carcinogenicity]
H411 (98.6%): Toxic to aquatic life with long lasting effects [Hazardous to the aquatic environment, long-term hazard]
P203, P261, P262, P264, P270, P271, P273, P280, P301+P316, P302+P352, P304+P340, P316, P318, P321, P330, P361+P364, P391, P403+P233, P405, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 72 reports by companies from 7 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.
H302: Harmful if swallowed [Warning Acute toxicity, oral]
H315: Causes skin irritation [Warning Skin corrosion/irritation]
H319: Causes serious eye irritation [Warning Serious eye damage/eye irritation]
H335: May cause respiratory irritation [Warning Specific target organ toxicity, single exposure; Respiratory tract irritation]
H351: Suspected of causing cancer [Warning Carcinogenicity]
H372: Causes damage to organs through prolonged or repeated exposure [Danger Specific target organ toxicity, repeated exposure]
P203, P260, P261, P264, P264+P265, P270, P271, P280, P301+P317, P302+P352, P304+P340, P305+P351+P338, P318, P319, P321, P330, P332+P317, P337+P317, P362+P364, P403+P233, P405, and P501 (click each P-code to see the statement)
H314: Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]
H318: Causes serious eye damage [Danger Serious eye damage/eye irritation]
H401: Toxic to aquatic life [Hazardous to the aquatic environment, acute hazard]
P260, P261, P262, P264, P264+P265, P270, P271, P273, P280, P301+P316, P301+P330+P331, P302+P352, P302+P361+P354, P304+P340, P305+P354+P338, P316, P317, P321, P330, P361+P364, P363, P391, P403+P233, P405, and P501 (click each P-code to see the statement)
If any symptoms, however slight, are noticed, the affected individual should be removed from contact with the chemical and placed under the care of a physician who is versed in the treatment necessary. (USCG, 1999)
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:
Note: Some foams will react with the material and release corrosive/toxic gases.
SMALL FIRE: CO2 (except for Cyanides), dry chemical, dry sand, alcohol-resistant foam.
LARGE FIRE: Water spray, fog or alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Avoid aiming straight or solid streams directly onto the product. Dike runoff from fire control for later disposal.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)
Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Advice for firefighters: Wear self-contained breathing apparatus for firefighting if necessary.
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
ACCIDENTAL RELEASE MEASURES; Personal precautions, protective equipment and emergency procedures: Wear respiratory protection. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. Methods and materials for containment and cleaning up: Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
SRP: Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in air, soil or water; effects on animal, aquatic and plant life; and conformance with environmental and public health regulations. If it is possible or reasonable use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination.
Product: Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber. Contaminated packaging: Dispose of as unused product.
Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the product.
Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed.
ACCIDENTAL RELEASE MEASURES; Personal precautions, protective equipment and emergency procedures: Wear respiratory protection. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.
For more Preventive Measures (Complete) data for Antimony trifluoride (9 total), please visit the HSDB record page.
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. A vapor-suppressing foam may be used to reduce vapors. DO NOT GET WATER INSIDE CONTAINERS. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Prevent entry into waterways, sewers, basements or confined areas.
SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. (ERG, 2024)
Keep container tightly closed in a dry and well-ventilated place. Store under inert gas. Keep in a dry place. Do not store in glass.
May be stored in glass vessels or steel drums. Keep well closed.
Biological Exposure Indices (BEI) [ACGIH] - Fluorides in urine = 2 mg/L prior to shift or 3 mg/L at end of shift; (Repeated measurements recommended.)
1.0 [mg/m3], as F, inhalable fraction[German Research Foundation (DFG)]
2.2 [mg/m3]
20 [mg/m3]
120 [mg/m3]
0.5 [mg/m3], as Sb (2.5 mg/m3, as F)
50.0 [mg/m3], as Sb
50 mg/cu m, as Sb /Antimony/
8 hr Time Weighted Avg (TWA): 2.5 mg/cu m. /Fluorides, as F/
Peak Exposure Recommendation: Transient increases in workers' exposure levels may exceed 3 times the value of the TLV-TWA level for no more than 15 minutes at a time, on no more than 4 occasions spaced 1 hour apart during a workday, and under no circumstances should they exceed 5 times the value of the TLV-TWA level. In addition, the 8-hour TWA is not to be exceeded for an 8-hour work period. /Fluorides, as F/
A4; Not classifiable as a human carcinogen. /Fluorides, as F/
Biological Exposure Index (BEI): Determinant: fluoride in urine; Sampling Time: prior to shift; BEI: 2 mg/L. Determinant: fluoride in urine; Sampling Time: end of shift; BEI: 3 mg/L. The determinant may be present in biological specimens collected from subjects who have not been occupationally exposed, at a concentration that could affect interpretation of the result. Such background concentrations are incorporated in the BEI value. The determinant is nonspecific, since it is also observed after exposure to other chemicals. /Fluorides/
For more Threshold Limit Values (TLV) (Complete) data for Antimony trifluoride (6 total), please visit the HSDB record page.
Approved respirator, rubber gloves. (USCG, 1999)
Eye/face protection: Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection: Handle with gloves.
Body Protection: Complete suit protecting against chemicals. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection: Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
For more Personal Protective Equipment (PPE) (Complete) data for Antimony trifluoride (12 total), please visit the HSDB record page.
Antimony trifluoride is a white to gray crystalline solid, which is sometimes shipped as an aqueous solution. It is corrosive to tissue. It is used in ceramics and to make other chemicals.
White to gray hygroscopic solid; [Hawley] White or light brown powder; [MSDSonline]
White orthorhombic crystals
Orthorhombic, deliquescent crystals
White to gray hygroscopic crystals
There are three known crystalline modifications.
BP: 376 °C. Also reported as BP 319 °C
376 °C @760 [mm Hg]
558 °F (USCG, 1999)
In water, 492 g/100 g water at 25 °C
In water, 443 g/100 mL at 20 °C; 562 g/100 mL water at 30 °C
Soluble in water
154 g/100 mL methanol; soluble in acetone
4.38 at 69.8 °F (USCG, 1999) - Denser than water; will sink
4.38 g/cu cm
4.379 @ 20°C
26.34 kPa (0.26 atm) at melting point
200 [mm Hg] @292 °C
Stable under recommended storage conditions.
Not flammable (USCG, 1999)
Hazardous decomposition products formed under fire conditions. - Hydrogen fluoride, Antimony oxide
When heated to decomp it emits very toxic fumes of /hydrogen fluoride/ and antimony.
102.8 kJ/mol at 298 K
Dissolves in water with limited hydrolysis, readily forms complexes such as antimony tetrafluoride and many soluble salts; deliquescent.
Hygroscopic
Heat of formation = -915.5 kJ/mol at 298.15 K
Enthalpy of fusion: -22.8 kJ/mol at mp
Entropy = 127 J/mol-K at 298 K; Entropy of fusion 38.2 J/mol-K; Enthalpy of fusion = -21.4 kJ/mol; Entropy of vaporization = 175.8 J/mol-K at 298 K
Metals -> Metalloid Compounds (Antimony)
Corrosives
Water slowly hydrolyzes antimony fluoride to form antimony (III) oxide. The dry powdered oxide ignites on heating in air [Mellor Vol. 9 425.1939].
Acids, Strong Non-oxidizing
Oxidizing Agents, Strong
Fluoride Salts, Soluble
Water-Reactive
A colorless, solid compound, toxic and corrosive. When heated to decomposition, it emits very toxic fumes of fluoride and metallic antimony [Lewis, 3rd ed., 1993, p. 83].
Trivalent antimony cmpd tend to form explosive mixtures with perchloric acid when hot. /Trivalent antimony cmpd/
Reacts dangerously with glass.
Strong oxidizers, acids, halogenated acids [Note: Stibine is formed when antimony is exposed to nascent (freshly formed) hydrogen.] /Antimony/
IDENTIFICATION AND USE: Antimony trifluoride exists in three known crystallin modifications. It is used to catalyze fluorinations by hydrogen fluoride, manufacture of chlorofluorides, in dyeing, usually in form of double salts, manufacture of pottery and porcelains. HUMAN STUDIES: Symptoms of exposure include severe gastritis or gastroenteritis with abdominal pain, retching, and prolonged vomiting, beginning 10-60 min after ingestion. Vomitus may become bloody. Diarrhea is observed, and the feces are watery and later tarry. Dehydration becomes intense. The exposure could further progress to shock, pallor, cyanosis, and coldness, rapid, weak or imperceptible pulse, low blood pressure, rapid and shallow respirations. Sometimes breathing is deep and rapid, reflecting an accompanying metabolic acidosis. Drowsiness, hyporeflexia, dilated pupils, coma could be observed. Vasomotor instability, shock or coma, and a serum iron level in great excess of the total iron binding capacity are poor prognostic signs. Liver injury can occur, consisting of hemorrhagic necrosis which is usually reversible. Death from shock, usually in 4-5 hr. Sometimes following apparent recovery, pneumonia with fever or secondary shock may cause death 1-3 days later. Among survivors, pyloric stenosis and mild hepatic cirrhosis may be encountered as persistent sequelae, but recovery is usually complete. ANIMAL STUDIES: Intratracheal administration in rats produced death at all doses greater than 1.5 mg. Lung, adrenal, and kidney weights increased in the antimony trifluoride-treated animals. In acute fluoride poisoning, fluoride ion increases capillary permeability and also produces a coagulation defect. These actions lead to hemorrhagic gastroenteritis and hemorrhages, congestion, and edema in various organs including the brain. Clinical manifestations include excitability, muscle tremors, weakness, urination, defecation, salivation, emesis, sudden collapse, clonic convulsions, coma, and death due to respiratory and cardiac failure. Chronic manifestations of excess fluoride in cattle are dental fluorosis and osteofluorosis. Chronic inhalation of subtoxic doses of antimony salts causes interstitial pneumonitis, intraalveolar lipoid deposits, and liver and cardiac damage.
A4; Not classifiable as a human carcinogen. /Fluorides, as F/
Occupational hepatotoxin - Secondary hepatotoxins: the potential for toxic effect in the occupational setting is based on cases of poisoning by human ingestion or animal experimentation.
Nephrotoxin - The chemical is potentially toxic to the kidneys in the occupational setting.
Dermatotoxin - Skin burns.
Toxic Pneumonitis - Inflammation of the lungs induced by inhalation of metal fumes or toxic gases and vapors.
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Fluorine and related compounds/
Basic treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary ... . Monitor for shock and treat if necessary ... . Anticipate seizures and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 mL/kg up to 200 mL of water for dilution if the patent can swallow, has a strong gag reflex, and does not drool. ... . Cover skin burns with dry sterile dressings after decontamination ... . /Fluorine and related compounds/
Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious, has severe pulmonary edema, or is in severe respiratory distress. Positive-pressure ventilation techniques with a bag valve mask device may be beneficial. Consider drug therapy for pulmonary edema ... . Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start IV administration of D5W /SRP: "To keep open", minimal flow rate/. Use 0.9% saline (NS) or lactated Ringer's (LR) if signs of hypovolemia are present. For hypotension with signs of hypovolemia, administer fluid cautiously. Consider vasopressors if patient is hypotensive with a normal fluid volume. Watch for signs of fluid overload ... . Treat seizures with diazepam or lorazepam ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Fluorine and related compounds/
/LABORATORY ANIMALS: Acute Exposure/ Intratracheal admin in rats produced death at all doses greater than 1.5 mg ... Lung, adrenal, and kidney weights increased in the antimony trifluoride-treated animals.
/LABORATORY ANIMALS: Acute Exposure/ ... Injecting trivalent antimony cmpd slowly into veins of rabbits, noted ... the appearance of normoblasts, stippled cells, increased number of reticulocytes and myelocytes in circulation within 24 hours. /Trivalent antimony cmpd/
/OTHER TOXICITY INFORMATION/ ... Focal pulmonary hemorrhage, fatty degeneration of liver ... changes in peripheral blood ... /reported/ ... in different species of animals ... . /Trivalent antimony cmpd/
/OTHER TOXICITY INFORMATION/ Chronic inhalation of subtoxic doses of antimony salts causes interstitial pneumonitis, intraalveolar lipoid deposits, and liver and cardiac damage. /Antimony salts/
SRP: Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in air, soil or water; effects on animal, aquatic and plant life; and conformance with environmental and public health regulations. If it is possible or reasonable use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination.
Product: Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber. Contaminated packaging: Dispose of as unused product.
/GUIDE 157 SUBSTANCES - TOXIC and/or CORROSIVE (Non-Combustible/Water-Sensitive)/ Fire or Explosion: Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. For UN1796, UN1826, UN2031 at high concentrations and for UN2032, these may act as oxidizers, also consult GUIDE 140. Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.). Substance may react with water (some violently), releasing corrosive and/or toxic gases and runoff. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or if contaminated with water. /Antimony compound, inorganic, solid, n.o.s.; Antimony compound, inorganic, liquid, n.o.s./
/GUIDE 157 SUBSTANCES - TOXIC and/or CORROSIVE (Non-Combustible/Water-Sensitive)/ Health: TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death. Reaction with water or moist air may release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. /Antimony compound, inorganic, solid, n.o.s.; Antimony compound, inorganic, liquid, n.o.s./
/GUIDE 157 SUBSTANCES - TOXIC and/or CORROSIVE (Non-Combustible/Water-Sensitive)/ Public Safety: CALL Emergency Response Telephone Number on Shipping Paper first. If Shipping Paper not available or no answer, refer to appropriate telephone number listed on the inside back cover. As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. Keep unauthorized personnel away. Stay upwind, uphill and/or upstream. Ventilate enclosed areas. /Antimony compound, inorganic, solid, n.o.s.; Antimony compound, inorganic, liquid, n.o.s./
/GUIDE 157 SUBSTANCES - TOXIC and/or CORROSIVE (Non-Combustible/Water-Sensitive)/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. /Antimony compound, inorganic, solid, n.o.s.; Antimony compound, inorganic, liquid, n.o.s./
For more DOT Emergency Guidelines (Complete) data for Antimony trifluoride (8 total), please visit the HSDB record page.
UN 3141; Antimony compound, inorganic, liquid, not otherwise specified
UN 1549; Antimony compound, inorganic, solid, not otherwise specified
IMO 6.1; Antimony compound, inorganic, solid, not otherwise specified; Antimony compound, inorganic, liquid, not otherwise specified
49 323 05; Antimony trifluoride, solution
49 323 35; Antimony trifluoride, solid (antimony salts other than liquid, not elsewhere classified)
No person may /transport,/ offer or accept a hazardous material for transportation in commerce unless that person is registered in conformance ... and the hazardous material is properly classed, described, packaged, marked, labeled, and in condition for shipment as required or authorized by ... /the hazardous materials regulations (49 CFR 171-177)./
The International Air Transport Association (IATA) Dangerous Goods Regulations are published by the IATA Dangerous Goods Board pursuant to IATA Resolutions 618 and 619 and constitute a manual of industry carrier regulations to be followed by all IATA Member airlines when transporting hazardous materials. Antimony compound, inorganic, solid, not otherwise specified and antimony compound, inorganic, liquid, not otherwise specified are included on the dangerous goods list. /Antimony compound, inorganic, solid, not otherwise specified; Antimony compound, inorganic, liquid, not otherwise specified/
The International Maritime Dangerous Goods Code lays down basic principles for transporting hazardous chemicals. Detailed recommendations for individual substances and a number of recommendations for good practice are included in the classes dealing with such substances. A general index of technical names has also been compiled. This index should always be consulted when attempting to locate the appropriate procedures to be used when shipping any substance or article. Antimony compound, inorganic, solid, not otherwise specified and antimony compound, inorganic, liquid, not otherwise specified are included on the dangerous goods list. /Antimony compound, inorganic, solid, not otherwise specified; Antimony compound, inorganic, liquid, not otherwise specified/