English Safety Data Sheet Database 中文版 MSDS

Diethoxydimethylsilane

CAS No. 78-62-6 | PubChem CID 62322
Section 1. Identification
Chemical NameDiethoxydimethylsilane CAS No.78-62-6
Synonymsdiethoxydimeth-ylsilane; dimethyldiethoxylsilane Chinese Name二乙氧基二甲基硅烷
Molecular FormulaC6H16O2Si Molecular Weight148.31
UN No.2380 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS02 · Flammable GHS07 · Irritant GHS09 · Environmental Hazard
Hazard Statements H225H315H319H332H335
Precautionary Statements P210P233P240P241P242P243P261P264P264+P265P271P280P302+P352P303+P361+P353P304+P340P305+P351+P338P317P319P321P332+P317P337+P317P362+P364P370+P378P403+P233P403+P235P405P501

Section 2. Hazards Identification

This chemical does not meet GHS hazard criteria for 2% (5 of 245) of reports.

H225 (98%): Highly Flammable liquid and vapor [Danger Flammable liquids]

H315 (62.9%): Causes skin irritation [Warning Skin corrosion/irritation]

H319 (62.9%): Causes serious eye irritation [Warning Serious eye damage/eye irritation]

H332 (17.1%): Harmful if inhaled [Warning Acute toxicity, inhalation]

H335 (11.8%): May cause respiratory irritation [Warning Specific target organ toxicity, single exposure; Respiratory tract irritation]

P210, P233, P240, P241, P242, P243, P261, P264, P264+P265, P271, P280, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P317, P319, P321, P332+P317, P337+P317, P362+P364, P370+P378, P403+P233, P403+P235, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 245 reports by companies from 12 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Reported as not meeting GHS hazard criteria per 5 of 245 reports by companies.

There are 11 notifications provided by 240 of 245 reports by companies with hazard statement code(s).

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

H225: Highly Flammable liquid and vapor [Danger Flammable liquids]

P210, P233, P240, P241, P242, P243, P280, P303+P361+P353, P370+P378, P403+P235, and P501 (click each P-code to see the statement)

Section 4. First-Aid Measures

Excerpt from ERG Guide 127 [Flammable Liquids (Water-Miscible)]:

Refer to the "General First Aid" section. Specific First Aid: Wash skin with soap and water. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· Wash skin with soap and water.

· In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 127 [Flammable Liquids (Water-Miscible)]:

CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient. CAUTION: For fire involving UN1170, UN1987 or UN3475, alcohol-resistant foam should be used. CAUTION: Ethanol (UN1170) can burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.).

SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.

LARGE FIRE: Water spray, fog or alcohol-resistant foam. Avoid aiming straight or solid streams directly onto the product. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· All equipment used when handling the product must be grounded.

· Do not touch or walk through spilled material.

· Stop leak if you can do it without risk.

· Prevent entry into waterways, sewers, basements or confined areas.

· A vapor-suppressing foam may be used to reduce vapors.

· Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers.

· Use clean, non-sparking tools to collect absorbed material.

Large Spill

· Dike far ahead of liquid spill for later disposal.

· Water spray may reduce vapor, but may not prevent ignition in closed spaces.

Excerpt from ERG Guide 127 [Flammable Liquids (Water-Miscible)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

· Consider initial downwind evacuation for at least 300 meters (1000 feet).

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

Section 7. Handling and Storage

Excerpt from ERG Guide 127 [Flammable Liquids (Water-Miscible)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

17 [mg/m3]

190 [mg/m3]

1100 [mg/m3]

CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient.

CAUTION: For fire involving UN1170, UN1987 or UN3475, alcohol-resistant foam should be used.

CAUTION: Ethanol (UN1170) can burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.)

Small Fire

· Dry chemical, CO2, water spray or alcohol-resistant foam.

Large Fire

· Water spray, fog or alcohol-resistant foam.

· Avoid aiming straight or solid streams directly onto the product.

· If it can be done safely, move undamaged containers away from the area around the fire.

Fire Involving Tanks, Rail Tank Cars or Highway Tanks

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Cool containers with flooding quantities of water until well after fire is out.

· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.

· ALWAYS stay away from tanks in direct contact with flames.

· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.

Excerpt from ERG Guide 127 [Flammable Liquids (Water-Miscible)]:

Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

Section 9. Physical and Chemical Properties

Dimethyldiethoxysilane appears as a colorless liquid. Less dense than water and insoluble in water. Vapors heavier than air.

114 °C @760 [mm Hg]

0.86 @25 °C

10 [mm Hg] @13.3 °C

29Si nuclear magnetic resonance spectrum

Boiling point

Chemical shift

Crystal structure

Dielectric constant

Heat of sublimation

Lineshape

Molar mass

Molecular structure

Optical coefficient

Refractive index

Spin-spin coupling constant

Sum formula

Vapor pressure

Viscosity

Flammable agents - 3rd degree

Section 10. Stability and Reactivity

Highly flammable. Insoluble in water.

Siloxanes

Highly Flammable

These substances undergo chemical reactions only under relatively severe circumstances or in the presence of an effective catalyst that promotes reaction. They are resistant to ignition, although they may become flammable at very high temperatures. They will be resistant to oxidation/reduction, except in the most severe conditions. These materials may be nontoxic.

Section 14. Transport Information

Flammable Liquid

Source: PubChem CID 62322 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:03:29.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.