Section 1. Identification
Chemical Name(Chlorosilyl)methane CAS No.993-00-0
Synonymschloromethylsilane; methylchlorosilane Chinese Name甲基氯硅烷
Molecular FormulaCH5ClSi Molecular Weight80.59
UN No.2534 Data SourcePubChem (NIH/NLM)
GHS Hazard Classification
Signal Word DANGER
Pictograms GHS02 · Flammable GHS04 · Compressed Gas GHS05 · Corrosive
Hazard Statements H220H261H280H314
Precautionary Statements P203P210P222P231+P232P260P264P280P301+P330+P331P302+P361+P354P304+P340P305+P354+P338P316P321P363P370+P378P377P381P402+P404P403P405P410+P403P501

Section 2. Hazards Identification

H220 (100%): Extremely flammable gas [Danger Flammable gases]

H261 (100%): In contact with water releases flammable gas [Danger Substances and mixtures which in contact with water, emit flammable gases]

H280 (100%): Contains gas under pressure; may explode if heated [Warning Gases under pressure]

H314 (100%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]

P203, P210, P222, P231+P232, P260, P264, P280, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P316, P321, P363, P370+P378, P377, P381, P402+P404, P403, P405, P410+P403, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 49 reports by companies from 1 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

Section 4. First-Aid Measures

Fresh air, rest. Half-upright position. Refer for medical attention.

Remove contaminated clothes. Rinse skin with plenty of water or shower.

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

Rinse mouth. Do NOT induce vomiting. Refer for medical attention .

Excerpt from ERG Guide 119 [Gases - Toxic - Flammable]:

Refer to the "General First Aid" section. Specific First Aid: In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)

General First Aid:

· Call 911 or emergency medical service.

· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.

· Move victim to fresh air if it can be done safely.

· Administer oxygen if breathing is difficult.

· If victim is not breathing:

-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.

-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).

-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.

· Remove and isolate contaminated clothing and shoes.

· For minor skin contact, avoid spreading material on unaffected skin.

· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.

· For severe burns, immediate medical attention is required.

· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.

· Keep victim calm and warm.

· Keep victim under observation.

· For further assistance, contact your local Poison Control Center.

· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.

Specific First Aid:

· In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts.

· In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin.

In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.

Section 5. Fire-Fighting Measures

Excerpt from ERG Guide 119 [Gases - Toxic - Flammable]:

DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.

SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.

LARGE FIRE: Water spray, fog or alcohol-resistant foam. FOR CHLOROSILANES, DO NOT USE WATER; use alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Damaged cylinders should be handled only by specialists.

FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)

Use alcohol-resistant foam, dry powder, carbon dioxide. NO water.

Section 6. Accidental Release Measures

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep unauthorized personnel away.

· Stay upwind, uphill and/or upstream.

· Many gases are heavier than air and will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).

· Ventilate closed spaces before entering, but only if properly trained and equipped.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· All equipment used when handling the product must be grounded.

· Do not touch or walk through spilled material.

· Stop leak if you can do it without risk.

· Do not direct water at spill or source of leak.

· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.

· FOR CHLOROSILANES, use alcohol-resistant foam to reduce vapors.

· If possible, turn leaking containers so that gas escapes rather than liquid.

· Prevent entry into waterways, sewers, basements or confined areas.

· Isolate area until gas has dispersed.

Excerpt from ERG Guide 119 [Gases - Toxic - Flammable]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.

SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 2534 datasheet.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions. (ERG, 2024)

Immediate precautionary measure

· Isolate spill or leak area for at least 100 meters (330 feet) in all directions.

· For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.

· For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind direction, as necessary.

· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions.

Small spill:

- ISOLATE in all directions: 30 m (100 ft)

Large spill:

- ISOLATE in all directions: 150 m (500 ft)

- PROTECT people from downwind during DAY time: 0.1 km (0.1 mi)

- PROTECT people from downwind during NIGHT time: 0.3 km (0.2 mi)

- PROTECT people from downwind during DAY time: 0.8 km (0.5 mi)

- PROTECT people from downwind during NIGHT time: 1.8 km (1.1 mi)

Remove all ignition sources. Evacuate danger area! Consult an expert! Personal protection: complete protective clothing including self-contained breathing apparatus. Collect leaking liquid in sealable containers. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations. Do NOT wash away into sewer.

Section 7. Handling and Storage

Excerpt from ERG Guide 119 [Gases - Toxic - Flammable]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Do not direct water at spill or source of leak. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. FOR CHLOROSILANES, use alcohol-resistant foam to reduce vapors. If possible, turn leaking containers so that gas escapes rather than liquid. Prevent entry into waterways, sewers, basements or confined areas. Isolate area until gas has dispersed. (ERG, 2024)

Fireproof. Ventilation along the floor. Cool. Dry. Store in an area without drain or sewer access.

Section 8. Exposure Controls / Personal Protection

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.

· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.

AEGL 1: Notable discomfort, irritation, or certain asymptomatic non-sensory effects. However, the effects are not disabling and are transient and reversible upon cessation of exposure (Unit: ppm)

AEGL 2: Irreversible or other serious, long-lasting adverse health effects or an impaired ability to escape (Unit: ppm)

AEGL 3: Life-threatening health effects or death (Unit: ppm)

AEGLs Status: Final

1.8 [ppm]

22 [ppm]

100 [ppm]

· DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.

Small Fire

· Dry chemical, CO2, water spray or alcohol-resistant foam.

Large Fire

· Water spray, fog or alcohol-resistant foam.

· FOR CHLOROSILANES, DO NOT USE WATER; use alcohol-resistant foam.

· If it can be done safely, move undamaged containers away from the area around the fire.

· Damaged cylinders should be handled only by specialists.

Fire Involving Tanks

· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.

· Cool containers with flooding quantities of water until well after fire is out.

· Do not direct water at source of leak or safety devices; icing may occur.

· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.

· ALWAYS stay away from tanks in direct contact with flames.

A harmful contamination of the air will be reached very quickly on evaporation of this substance at 20 °C.

The substance is corrosive to the eyes, skin and respiratory tract. Corrosive on ingestion. Inhalation may cause lung oedema. The effects may be delayed. Medical observation is indicated.

Repeated or prolonged inhalation may cause effects on the lungs. The substance may have effects on the lungs. This may result in chronic bronchitis.

Excerpt from ERG Guide 119 [Gases - Toxic - Flammable]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

NO open flames, NO sparks and NO smoking.

AVOID ALL CONTACT!

Use local exhaust or breathing protection.

Protective gloves. Protective clothing.

Wear safety goggles or eye protection in combination with breathing protection. Wear face shield.

Do not eat, drink, or smoke during work.

Section 9. Physical and Chemical Properties

Methyl chlorosilane is a colorless gas with a distinctive odor. It is insoluble in water. Its vapors are heavier than air. Contact with the material causes severe irritation to skin, eyes, and mucous membranes. It is toxic by ingestion and skin absorption. It is also a dangerous fire risk. It is used to make water repellent materials. Prolonged exposure of container to fire or intense heat may result in their violent rupturing and rocketing.

COLOURLESS LIQUID.

-45 °C @760 [mm Hg]

Solubility in water: reaction

Vapor pressure, kPa at 20 °C: 18.3

Schoenflies notation

Chemical bond

Chemical shift

Internuclear distance

Molecular structure

Nuclear quadrupole coupling

Nuclear quadrupole moment

Point group

Rotational excitation cross section

Spin-spin coupling constant

Vibrational mode frequency

Corrosives

Flammable agents - 4th degree

Reactive agents - 2nd degree

Section 10. Stability and Reactivity

Highly flammable. Based on the properties of similar materials, there is the possibility that the reaction of this compound with water may be vigorous or violent. Products of the reaction include hydrogen chloride. The reaction generates heat and this heat may be sufficient to ignite the product. The chlorosilicon hydrides (ClxSiHy) are spontaneously flammable in air [NFPA 1991].

Chlorosilanes

Highly Flammable

Water-Reactive

Pyrophoric

Chlorosilanes, such as METHYLCHLOROSILANE, are compounds in which silicon is bonded to from one to four chlorine atoms with other bonds to hydrogen and/or alkyl groups. Chlorosilanes react with water, moist air, or steam to produce heat and toxic, corrosive fumes of hydrogen chloride. They may also produce flammable gaseous H2. They can serve as chlorination agents. Chlorosilanes react vigorously with both organic and inorganic acids and with bases to generate toxic or flammable gases.

Section 11. Toxicological Information

The substance can be absorbed into the body by inhalation.

Burning sensation. Cough. Laboured breathing. Shortness of breath. Sore throat. Symptoms may be delayed.

Redness. Pain. Skin burns.

Pain. Redness. Severe deep burns.

Abdominal pain. Burning sensation. Shock or collapse.

Section 14. Transport Information

Poison Gas Flammable Gas Corrosive

UN Hazard Class: 2.3; UN Subsidiary Risks: 2.1 and 8

Source: PubChem CID 61244 (NIH/NLM, public domain). Retrieved from PubChem, a public-domain chemistry database maintained by the U.S. National Library of Medicine. Last updated: 2026-08-02 09:10:15.
Disclaimer: This information is compiled for reference only and does not replace the manufacturer's official Safety Data Sheet. Always consult the supplier's SDS before handling any chemical.